CHAP.07 - USAGE AND MAINTENANCE FOR THE USER
07.1 STOVE OPERATION
The STOVE uses pellets as fuel, whose combustion is electronically controlled.
Pellets are taken from the storage hopper (A) by the auger (B) controlled by the gear motor (C) and conveyed directly to the combus-
tion crucible (D). They are ignited by the hot air produced by the electric heating element (E) and aspirated into the crucible by the cen-
trifugal fan (F ) which is the same that sucks up the fumes produced by combustion, expelling them to the rear part of the stove.
The fan/s (G) move/s air in the air space on the back of the fireplace, where it is heated and then released into the environment through
the front slit (H)(10 kW stove) and the ductible air rear outlets (I) (15kW stove). Located on the rear part of the stove, the hopper (A) is
filled by an openable lid (L) located on the upper part of the cladding.
The fireplace is equipped with an exchanger in steel and dual heat developing FIREFLECTOR, closed in front by a door in ceramic
glass.
The quantity of fuel, the feeding of comburent air and the extraction of fumes are regulated with an electronic card in order to obtain a
highly efficient combustion.
All the operations for managing machine functions are handled by a supplied radio remote control. It it breaks or is lost, the emergency
console inside on the back of the stove (see par. 07.3) can be used to start up or turn off the stove.
I
A
B
C
G
07.2 DOOR OPENING
Open the stove's door by pulling the lever on the right (A) forward.
A
H
L
E
D
F