AFi RT-913 Instruction Manual

Video transmitter with bi-directional multi-protocol data

Advertisement

Quick Links

Instruction Manual

RT-913
Video Transmitter With
Bi-directional Multi-Protocol Data
© Copyright 2005, American Fibertek, Inc. 0824JD

Advertisement

Table of Contents
loading

Summary of Contents for AFi RT-913

  • Page 1: Instruction Manual

    Instruction Manual RT-913 Video Transmitter With Bi-directional Multi-Protocol Data © Copyright 2005, American Fibertek, Inc. 0824JD...
  • Page 2: Table Of Contents

    Video Input Connection ................4 Data Input / Output Connections ..............5 Typical System Data Connections............... 5 Data Configuration..................5 RS485 Data Signals ..................6 Offset Bias - RS485 ..................6 RT-913 Status LED Indicators ..............7 Warranty ...................... 8...
  • Page 3: Functional Description

    The RT-913 multiplexes a single video input signal along with up to three data signals into a high speed serial data stream. This serial data stream modulates a laser at 1310 nm wavelength. The RT-913 also detects and demultiplexes a return optical serial data stream signal containing up to three data channels at 1550 nm wavelength.
  • Page 4: Installation

    INSTALLATION THIS INSTALLATION SHOULD BE MADE BY A QUALIFIED SERVICE PERSON AND SHOULD CONFORM TO THE NATIONAL ELECTRICAL CODE, ANSI/NFPA 70 AND LOCAL CODES. The unit slides into any open slot in the SR-20 or SR-20D subrack. Use a small screwdriver to push and lock the two ¼...
  • Page 5: Data Input / Output Connections

    Correspondingly, the receiver of an electronic signal is labeled RX or Data In. Following this standard, the Data Out of the copper device is connected to the Data In of the RT-913. The plus terminal of the copper device is connected to the plus terminal of the RT-913 and the minus is connected to the minus.
  • Page 6: Rs485 Data Signals

    In order to reconfigure the RS485/422 channel, the rack card cover needs to be removed. To open the RT-913, remove the two screws at the left rear of unit near data and fiber connections. Also remove the two screws at the right front of unit (top of cover). The configuration switch banks are located at the lower right corner of PCB next to the data terminals (See drawing below).
  • Page 7: Rt-913 Status Led Indicators

    Data Flow Not Detected DATA RX A green LED indicator is provided to monitor the data coming in from the fiber, through the RT-913, and out onto the electrical interface. The intensity of this indicator will vary with input data patterns, however in typical applications it will cycle on and off as data is received.
  • Page 8: Warranty

    SYNC A bi-color LED indicator is provided to monitor the proper serialization of the electrical data stream through the RT-913 and out onto the fiber. DC power and sync status associated with this LED is summarized below. Sync LED DC Power Status...