10.4
Protective tube
- Remove drive shaft,
see 10.3.
- Remove cowhorn handle or
looped handle,
see 10.1 or 10.2.
•
Undo clamping screws on con-
trol handle of machines with
looped handle.
1
2
•
Remove locating screw (1) from
AV sleeve.
•
Undo clamping screw (2).
46
2
1
- Pull out protective tube.
•
On machines with looped hand-
le, pull protective tube (1) out of
control handle (2) at the same
time.
•
Remove throttle cable holder, if
fitted.
•
Remove bolts from carrying ring.
•
Pully carrying ring apart and
remove it.
The parts are installed in reverse
order.
•
Push protective tube in until the
holes line up.
- Torque locating screw down to
2.5 Nm and clamping screw to
5.5 Nm.