Martin MAC III User Manual page 47

Wash
Hide thumbs Also See for MAC III:
Table of Contents

Advertisement

Menu level 1
Menu level 2
FIRMWARE
VERSION
POWER ON TIME
LAMP ON TIME
FIXTURE
LAMP STRIKES
INFORMATION
AIR FILTERS
MAC ID
SERIAL NUMBER
RDM UID
FAN SPEED*
TEMPERATURE*
POWER UNIT
EVENT LOG VIEWER
RATE
QUALITY
DMX LIVE*
START CODE
STROBE/SHUTTER → FIXTURE ADJUSTMENTS
ACTION
TEST
REPEAT
SEQUENCE*
STATUS → DURATION
RESET
MANUAL
LAMP ON/OFF
CONTROL*
STROBE/SHUTTER → TILT
Menu level 3
Menu level 4
Vxx.xx.xx
TOTAL POWER ON
RESETTABLE POWER ON
CLEAR RESETTABLE POWER ON
TOTAL LAMP ON
RESETTABLE LAMP ON
CLEAR RESETTABLE LAMP ON
SET TIME ALERT
TOTAL LAMP STRIKES
RESETTABLE LAMP STRIKES
CLEAR RESETTABLE LAMP STRIKES
RESETTABLE AIR FILTER
SET TIME ALERT
CLEAR RESETTABLE AIR FILTER
xx.xx.xx.xx.xx.xx
(xx)xxxxxxxxxxxx
0x4D50.xxxxxxxx
Start / Stop / Pause
On / Off
ACTION
ACTION
Table 3: Control menus
Control panel menus
Notes (Default settings in bold print)
Fixture software version
Display hours fixture has been powered on
since manufacture (not user-resettable)
Display hours fixture has been powered on
since last counter reset (user-resettable)
Reset RESETTABLE POWER ON counter
to zero.
Display hours of lamp use since
manufacture
(not user-resettable)
Display hours of lamp use since last
counter reset (user-resettable)
Reset RESETTABLE LAMP ON counter
to zero.
Set number of hours before LTIM lamp
lifetime warning message is displayed.
Display number of times lamp has been
struck since manufacture (not
user-resettable)
Display number of times lamp has been
struck since last counter reset
(user-resettable)
Reset RESETTABLE LAMP STRIKES
counter to zero.
Display hours fixture has been powered on
since timer was last cleared.
Set alert timer from 0 - 750 hours.
Resets AIR FILTER timer to zero.
Fixture's MAC address
Fixture's serial number
Fixture's unique RDM ID
Displays speed in RPM of all cooling fans
Displays temperature in °C of all PCBs and
of ballast capacitor
Displays voltage at mains power input,
voltage, current and wattage at lamp
terminals, lamp status, igniter status and
lamp intensity.
Views fixture event log
DMX transmission speed in packets per
second
Percent of packets received
Value of the DMX start code
DMX value (0 - 255) received on each
channel
Run test sequence of all functions
Enable auto-repeat of test sequence
Scene status information for test sequence
Click jog wheel to reset fixture
Manually strike/douse lamp
Set each effect manually.
47

Advertisement

Table of Contents
loading

Table of Contents