Installing GR3

5.1 Mounting the unit

The GR3 can be used as a stand-alone unit
and placed on a hard surface or rack-mounted
in a standard 19" profile.
You will need the following items;
 T10 Torx screwdriver
 Small flat blade screwdriver
 Hex Screwdriver
 Rack ears (supplied)
 4 x M3 Torx screws (supplied)
 4 x M6 Screws
To rack-mount the unit follow the below
procedure;
1.
Using the supplied rack ears and M3 Torx
screws fit to the unit as in the below
diagram.
Be sure to use the supplied screws or
exact replacements (damage to internal
PCB's can result when using longer
screws).
GR3 User Guide
Rackear
M3 Torx Screw
M3 Torx Screw
10
2.
Using the small flat bladed screwdriver
gently remove the four rubberized feet on
the base of the unit.
3.
Install within the 19" rack making sure the
unit is secure.
Please ensure you have enough depth
within the rack to accommodate the GR3
together with sufficient cable bending
radius (the GR3 is 220mm deep).