4.3 Water supply connection

Important
Make sure that the water connection line of the machine is connected to a potable water supply with
an operating pressure ranging from 0.5 to 2 bar. In case of an operating pressure of more than 2
bars, use a pressure regulator.
Please note that often times the pressure of the water supply may vary. If the water supply pressure
temporarily exceeds 2 bars, use a pressure regulator. Furthermore, a shut-off valve should be used.
This valve should be located where it is easily reached, so that the water supply can be interrupted at
any time.
Position "0": water tank
Machine in use with a direct water connection
The water connecting hose is to be connected to the water supply adapter (image 1).
When using the machine with direct water supply, the valve has to be turned towards the opposite side of the water
supply adapter opening (image 1). The water supply adapter is located in the rear part of the bottom panel (image
1). Additionally, place the switch behind the drip tray into position "1" (image 2). Please make sure that your water
tap is always open during water-connection usage so that the machine never runs out of water!
Image 1
Important
Do not leave the machine switched on or unattended when not in use.
Make sure to close the shut off valve of the water connection and to switch off the electric main
switch or to disconnect the power plug when the machine is not in use.
Machine in use with a water tank
When using the machine with a water tank, please turn the valve towards the water supply adapter (image 3).
Additionally, place the switch behind the drip tray into position "0" (image 4).
Image 3
Valve in position "1" for operating
machine
with
direct
connection
Place switch into position "1" for
direct water connection
Water supply adapter
Valve in position for operating
machine with water tank
Place switch into position "0" when
operating machine with water tank
Position "1": direct water connection
Image 2
water
Image 4