Objet350 User Guide
Photo-
Follow these instructions for photobleaching printed models.
Bleaching
• The fluorescent lamps should be rated 45W, 6500K.
Instructions
• When using desk lamps, place the models in a container lined with
• Arrange the models with enough space between them to allow light to
• Verify that the ambient temperature around the models is approximately
• Inspect the models after six hours of treatment.
More information about this treatment is available in the application note
VeroClear RGD810 Model Material.
Storing Models
Models are cured as they are printed, making them safe and stable for a long
time. However, proper storage conditions are necessary to prevent deforming.
• Keep printed models at room temperature and in a low-humidity
• Do not expose models to direct sunlight and other heat sources.
DOC-17001 Rev. G
aluminum foil. Use at least two lamps, more when treating models in a
large container.
reach all sides of each model.
40°C (104°F). Higher temperatures may cause model distortion; lower
temperatures may not produce satisfactory results. When using desk
lamps, you can achieve the required temperature by positioning the lamps
approximately 10 cm (4 in.) above the models.
❒ For parts with a matte finish, this should be enough. Polish and
lacquer the parts.
❒ For parts with a glossy finish, continue the photobleaching treatment
for up to 18 hours more.
In Stratasys laboratories, there was a tint reduction of approximately 70%
within six hours. After 24 hours, tint was reduced by approximately 90%.
environment.
7 Handling Printed Models