Gree GMV-PD100W/NAB-K Service Manual page 41

Dc inverter multi vrf
Table of Contents

Advertisement

7.1.3 Display View
1
PAGE
16
CENTER
CTRL MODE
SINGLE SELECT
Pagination/displays
1
present domain
2
Present unit no.
3
Error
4
Operation mode
5
Speed display
6
Check
7
Error code
Operation monitoring and
8
controlling /monitoring
9
System time
10
Timer setting
11
Pre-set temperature
12
Swing and Defrost
13
Ambient temperature
14
System setting
15
Control mode
16
Displays of soft address
Instruction to display interface:
System Setting: Including Address Setting and other functions, and it is set when installation personnel are
adjusting units. It is not recommended that users operate it. The usage of this function requires password.
modules displayed by central control (hereinafter called soft addresses), and the addresses of communication
modules themselves (hereinafter called hard addresses) are value from 0~254, thus there is address matching
problem between central control and controlled communication module. In order to solve this problem, address
mapping setting is required to be conducted before project adjusting!
2
3
AUTO
INDOOR UNIT
ERROR
ROOM TEMP.
IN-
DOOR
DO
SWING SLEEP MELT
MAIN
SYS
ADDRESS
SET
INITIALIZE
Mon. Tue. Wed.
Thu. Fri. Sat. Sun.
15
14
Fig.7.1.3
Under select control mode, group no. that is present controlling is displayed;
Under addresses setting state, present Soft Add is displayed.
Displays the soft address of communication module that the present checking or
controlling indoor unit is belonged as well as the address of indoor unit;
Format: Soft add—Indoor unit add
Displays when there is error at any indoor or outdoor unit.
Displays every operation state mode of indoor unit
Displays High, Medium, Low and Auto speed of indoor unit
Under group control mode, it is displayed when checking grouping information;
Under address setting mode, it is displayed when checking hard address.
Displays when abnormal occur on operation state of present indoor unit.
When central control works in normal, operation monitoring displays; when control
signal is transmitted, operation monitoring and controlling is displayed.
Displays present time, format is Y, M, D, H, M and week.
Timer On/Off on when Timer On/Off is set to present indoor unit
Displays value of pre-set temperature
Displays operation of swing at indoor unit and defrost at outdoor unit
Displays value of ambient temperature of present indoor unit
Setting operation mode of central control. It should be completed
by installation personnel, but not for users.
Displays 3 control modes of Central, Single and Select controls
When Indoor on, addresses of present online indoor unit is displayed;
When domain on, soft address of present online communication module is displayed;
4
COOL DRY FAN HEAT AUTO LOW
SET TEMP.
ERR CODE
c
c
TIMER ON OFF
Year
MonD
13
12
11
10
DC Inverter Multi
VRF Service Manual
5
MID HIGH
6
CHECK
TEST
7
MONITORING
8
DETECTING
ate
Hour
Min