Page 1
Owner's Manual Original Instructions Commercial Air Conditioners Multi Variable Air Conditioners Wall Mounted Type Indoor Unit Models GMV-N22~71G/A3A-K GMV-N22~71G/A2A-K GMV-N22~71G/A4A-K GMV-N22~71G/A8A-K GMV-N22~71G/C9A-K GMV-N22~71G/E3A-K GMV-N22~71G/A3A-D GMV-N22~71G/A8A-D GMV-N22~71G/E3A-D GMV-N22~71G/B3A-D GMV-ND22~100G/A3A-T GMV-ND22~100G/A8A-T...
Page 2
To Users Thank you for selecting Gree product. Please read this instruction manual carefully before installing and using the product, so as to master and correctly use the product. In order to guide you to correctly install and use our product and achieve expected...
Page 3
Exception Clauses Manufacturer will bear no responsibilities when personal injury or property loss is caused by the following reasons: (1) Damage the product due to improper use or misuse of the product; (2) Alter, change, maintain or use the product with other equipment without abiding by the instruction manual of manufacturer;...
Contents 1 Safety Notices (Please be sure to abide ) ............1 2 Product Introduction ..................3 2.1 Outline of the Unit and Main Parts ..................3 2.2 Rated Operating Condition ....................... 4 3 Preparations for Installation ................4 3.1 Location for Installation ....................4 3.2 Schematic diagram of installation spaces..............
Multi Variable Air Conditioners Wall Mounted Type Indoor Unit 1 Safety Notices (Please be sure to abide ) Warning: If not abide strictly, it may cause severe damage to the unit or the people. Note: If not abide strictly, it may cause slight or medium damage to the unit or the people.
Page 6
Multi Variable Air Conditioners Wall Mounted Type Indoor Unit Never fail to comply with the nitrigen charge Never short-circiut or cancel requirements.Charge the pressure switch to prevent nitrogen when welding unit damage. pipes. Please firstly connect the Before using the unit, please wired controller before check if the piping and wiring energization,otherwise...
Any personal injury or property loss caused by improper installation, improper debug, unnecessary repair or not following the instructions of this manual should not be the responsibility of Gree Electric Appliances, Inc. of Zhuhai. 2 Product Introduction 2.1 Outline of the Unit and Main Parts...
① The unit shall be installed by the professional personnel according to this installation instruction to ensure proper use. ② Please contact the local Gree appointed service center before installation. Any malfunctioncaused by the unit that is not installed by the Gree appointed service center...
Multi Variable Air Conditioners Wall Mounted Type Indoor Unit would probably not be dealt with on time because of the inconvenience of the business contact. ③ It should be guided under the professional personnel when the air conditioner unit is moved to other place.
Multi Variable Air Conditioners Wall Mounted Type Indoor Unit 3.3.2 Select communication line for indoor unit and indoor unit (outdoor unit) Fig 3.3.2 Total Length L (m/feet) of Communication Cable Wire size Material Type Material Standard Remarks between Indoor Unit and /AWG) Indoor (Outdoor) Unit 1.If the wire diameter is...
Page 11
Sectional Sectional Area Model Power Cord Size apacity Area of of Power Ground Cord(mm Wire(mm GMV-N56G/A3A-K, GMV-N56G/A2A-K GMV-N56G/A4A-K, GMV-N56G/A8A-K 220-240V ~ 50Hz GMV-N56G/C9A-K, GMV-N56G/E3A-K GMV-N63G/A3A-K, GMV-N63G/A2A-K GMV-N63G/A4A-K, GMV-N63G/A8A-K 220-240V ~ 50Hz GMV-N63G/C9A-K, GMV-N63G/E3A-K GMV-N71G/A3A-K, GMV-N71G/A2A-K GMV-N71G/A4A-K, GMV-N71G/A8A-K 220-240V ~ 50Hz...
Multi Variable Air Conditioners Wall Mounted Type Indoor Unit 4 Installation Instructions 4.1 Installation of Indoor Unit Fig 4.1 Below are dimensions of W, H, D for different models: Unit: mm Item Model GMV-N22~28G/A3A-K GMV-N22~28G/A2A-K GMV-N22~28G/A4A-K GMV-N22~28G/A8A-K GMV-N22~28G/C9A-K GMV-N22~28G/E3A-K GMV-N22~28G/A3A-D GMV-N22~28G/A8A-D GMV-N22~28G/E3A-D GMV-N22~28G/B3A-D...
Multi Variable Air Conditioners Wall Mounted Type Indoor Unit Item Model GMV-ND80~100G/A3A-T 1350 GMV-ND80~100G/A8A-T 4.2 The installation of the rear panel Unit: mm Fig 4.2 ① Find the horizontal position with the gradienter; Since the drainage pipe is on the left side, it is necessary to adjust the rear panel to make its left side a little bit lower.
Multi Variable Air Conditioners Wall Mounted Type Indoor Unit Fig 4.4 4.5 Installation the connection pipes Connect the ends of the connection pipe with two leading pipes, and then tighten the joint nuts tightly. Connect the connect pipe with the two relative leading pipe, tie the nut on tie –in of the connect pipe tightly.
Multi Variable Air Conditioners Wall Mounted Type Indoor Unit 2) Remove the wiring screws on the terminal board. 3) Shape the tail of wire into ring by needle nose plier, and keep the gauge of ring in accordance with screw. 4) Use the screwdriver for tightening the terminal.
Multi Variable Air Conditioners Wall Mounted Type Indoor Unit (3) Connect the communication line to terminal D1 and D2 on the 4-digit wiring board of indoor unit, as shown in Fig.5.3.1. Fig 5.3.1 Fig 5.3.2 (4) Secure the communication line with the wire clamp on the electric box. (5) In order to ensure the reliability of communication between IDU and ODU and the communication among each IDU, add a matched resistance(supplied in a package before ex-factory) on the wiring board of the last indoor unit in a series connection.
Multi Variable Air Conditioners Wall Mounted Type Indoor Unit controllers should be different through address setting. Address 1 is for main controller; Address 2 is for slave controller. Detailed setting please refer to the instruction manual of wired controller. 5.6 Installation of the indoor unit (1) When routing the piping and wiring from the left or right side of the indoor unit, it is necessary to cut off the tailings of the pipe left on the holder of the unit.
Multi Variable Air Conditioners Wall Mounted Type Indoor Unit (4) Prevent the cooled air blowing to body directly for long time and making indoor temperature too low, for it is bad for health. (5) Do not pour water to unit or clean it by water, otherwise a malfunction or electric shock may happen.
Multi Variable Air Conditioners Wall Mounted Type Indoor Unit As shown in Fig.7.2.1, open the surface panel by holding the both ends of groove along the arrow direction, and then take the air filter out downward. (2) Clean the filter . Use cleaner or water to wash the filter;...
Multi Variable Air Conditioners Wall Mounted Type Indoor Unit Error Error Error Content Content Content Code Code Code Ambient Temperature Sensor Anti-freezing Protection Indoor Unit CO Sensor Error Error No Master Indoor Unit Inlet Pipe Temperature Sensor Communication Error Error Error Power Insufficiency Outlet Pipe Temperature Sensor...
Multi Variable Air Conditioners Wall Mounted Type Indoor Unit 9.1 Service center When the following phenomena appeared, please stop operating immediately, cut off the main power supply of the unit and then contact the service center of the air conditioner. (1) Harsh sound heard when running;...