Brother FAX-170 Service Manual page 102

Hide thumbs Also See for FAX-170:
Table of Contents

Advertisement

Selector
No.
1
Earth function in transfer facility
2
Dual tone detection frequency
in ICM recording
3
Tone detection level in ICM
4
recording
5
Earth time length for earth
function
6
7
Break time length for flash
function
8
NOTE: Selectors 1 and 5 through 8 are not applicable in those countries where no transfer fa-
cility is supported.
Selector 1:
Earth function in transfer facility
This selector determines whether or not the earth function is added to the transfer setting
menu to be accessed by the function switch.
Selectors 5 and 6: Earth time length for earth function
These selectors set the short-circuiting time length of the telephone line (La or Lb) to ground.
This setting is effective only when the earth function is selected for the R key by using the
function switch.
Selectors 7 and 8: Break time length for flash function
These selectors set the break time length.
This setting is effective only when the flash function is selected for the R key by using the
function switch.
WSW04 (TRANSFER facility setting)
Function
V – 14
Setting and Specifications
0:
Provided
1: Not provided
No. 2
3
0
0
:
350 + 440 Hz (A)
0
1
:
440 + 480 Hz (B)
1
x
:
480 + 620 Hz (C)
0: OFF
1: High
No. 5
6
0
0
:
200 ms
0
1
:
300 ms
1
0
:
500 ms
1
1
:
700 ms
No. 7
8
0
0
:
80 ms
0
1
:
110 ms
1
0
:
250 ms
1
1
:
500 ms

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents