Selector
No.
1
Min. OFF time length of calling
signal (Ci)
2
3
Max. OFF time length of calling
signal (Ci)
4
5
Detecting time setting
6
7
Delay
8
Not used.
Selectors 1 through 4:
If the equipment detects the OFF state of calling signal (Ci) for a time length which is greater
than the value set by selectors 1 and 2 and less than the value set by selectors 3 and 4, it
interprets the Ci signal as OFF.
Selectors 5 and 6: Detecting time setting
These selectors set the time length required to make the equipment acknowledge itself to be
called. That is, if the equipment continuously detects calling signals with the frequency set
by selectors 1 through 4 of WSW14 during the time length set by these selectors 5 and 6, it
acknowledges the call.
Selector 7:
Delay
Setting this selector to "0" allows the equipment to insert a 900 ms WAIT after
acknowledgement of the call until the equipment turns on the CML relay to start receiving
operation.
WSW12
(Signal detection condition setting)
Function
Min. and max. OFF time length of calling signal (Ci)
V – 24
Setting and Specifications
No. 1
2
0
0
:
300 ms
0
1
:
500 ms
1
0
:
700 ms
1
1
:
900 ms
No. 3
4
0
0
:
6 sec.
0
1
:
7 sec.
1
0
:
9 sec.
1
1
:
11 sec.
No. 5
6
0
0
:
800 ms (1000 ms*)
0
1
:
200 ms
1
0
:
250 ms
1
1
:
150 ms
0: Yes
1: No
* 1000 ms in Chinese or Hong Kong versions.