until the pressure reading on the gauge is the same
as it was in step 7.
Figure 22
1. Boom bypass valves
11. Turn the boom on and off to verify the pressure
does not change.
12. Repeat steps 9 through 11 for the other booms.
13. Drive the sprayer at the desired speed while spraying
and turn each boom off individually. The pressure
on the gauge should not change.

Pump

The pump is located near the back of the tank on the
left side (Figure 23).
Figure 23
1. Pump
2. Grease fitting
Adjusting the Air Pressure in
Dampener
The air pressure in the dampener on the pump is set at
15 psi (1 bar) by the manufacturer. The recommended
3. Pressure dampener
pressure in the dampener is 1/3 of the spraying
pressure. If using a spray pressure greater than 45 psi
(3.1 bar) adjust the dampener accordingly.

Transporting the Sprayer

For moving the sprayer long distances, use a trailer.
Secure the sprayer to the trailer.Figure 24 and
Figure 25illustrate the tie-down points.
1. Tie down points
1. Rear tie-down point

Towing the Sprayer

In case of an emergency, the sprayer can be towed for a
short distance after you open the tow valve. However,
we do not recommend this as a standard procedure.
Towing at excessive speeds could cause a loss
of steering control, resulting in personal injury.
Never tow the sprayer faster than 3 mph (4.8
kph).
28
Figure 24
Figure 25

Advertisement