Before Operating
Before servicing or making adjustments to the machine,
stop the engine and remove the key from the switch.
CHECK THE ENGINE OIL (Fig. 2 & 3)
Crankcase capacity is 5 l with filter.
1.
Park the machine on a level surface. Release the hood latch
and open the hood.
2.
Remove the dipstick from the tube cap, wipe clean and rein-
stall the dipstick into the tube cap. Pull it out again and check
the oil level on the dipstick: The oil level must always be in the
notch area on the dipstick.
3.
If the oil level is low, remove the tube cap and add SAE 15W-
40 CD oil until the level reaches top of notch on the dipstick.
DO NOT OVERFILL.
4.
Install the oil tube cap.
5.
Close the hood and secure the latch.
CHECK THE COOLING SYSTEM (Fig. 4)
If the engine has been running, pressurized hot coolant
can escape and cause burns if the degasser cap is
removed. Allow the engine to cool at least 15 minutes or
until the degasser cap is cool enough to touch without
burning your hand.
Capacity of the system is 13 l.
Check the cooling system if the low water level light illuminates.
1.
Park the machine on a level surface. Release the hood latch
and open the hood.
10
CAUTION
CAUTION
Figure 2
1.
Hood latch
Figure 3
1.
Dipstick/tube cap
Figure 4
1.
Degasser tank