Maintenance and Storage
Make sure all hydraulic line connectors are tight and all
hydraulic hoses and lines are in good condition before
applying pressure to the system.
Keep your body and hands away from pin hole leaks or
nozzles that eject hydraulic fluid under high pressure.
Use paper or cardboard, not your hands, to search for
leaks. Hydraulic fluid escaping under pressure can have
sufficient force to penetrate the skin and cause serious
injury. Seek immediate medical attention if fluid is
injected into skin.
Before disconnecting or performing any work on the
hydraulic system, all pressure in the system must be
relieved by stopping the engine and lowering the deck and
attachments to the ground.
Check all fuel lines for tightness and wear on a regular
basis. Tighten or repair them as needed.
If the engine must be running to perform a maintenance
adjustment, keep hands, feet, clothing, and any parts
of the body away from the deck, attachments, and any
moving parts, especially the screen at the side of the
engine. Keep everyone away.
If major repairs are ever needed or if assistance is desired,
contact an Authorized Toro Distributor.
Use only Toro approved attachments and replacement
parts. The warranty may be voided if used with
unapproved attachments.

Sound Power Level

This unit has a guaranteed sound power level of 105 dBA,
which includes an Uncertainty Value (K) of 1 dBA.
Sound power level was determined according to the
procedures outlined in ISO 11094.

Sound Pressure Level

This unit has a sound pressure level at the operator's ear of 90
dBA, which includes an Uncertainty Value (K) of 1 dBA.
Sound pressure level was determined according to the
procedures outlined in EN 836.

Vibration Level

Hand-Arm
Measured vibration level for right hand = 1.25 m/s
Measured vibration level for left hand = 1.28 m/s
Uncertainty Value (K) = 0.5 m/s
Measured values were determined according to the procedures
outlined in EN 836.
2
2
2
Whole Body
Measured vibration level = 0.37 m/s
Uncertainty Value (K) = 0.5 m/s
Measured values were determined according to the procedures
outlined in EN 836.