Omron Elite 7300W Instruction Manual

Women's advanced automatic blood pressure monitor with two cuffs
Hide thumbs Also See for Elite 7300W:

Advertisement

INSTRUCTION MANUAL
Women's Advanced
Automatic Blood Pressure Monitor
with Two Cuffs
Elite 7300W
Model
Downloaded from
www.Manualslib.com
manuals search engine

Advertisement

Table of Contents
loading

Summary of Contents for Omron Elite 7300W

  • Page 1 INSTRUCTION MANUAL Women’s Advanced Automatic Blood Pressure Monitor with Two Cuffs Elite 7300W Model Downloaded from www.Manualslib.com manuals search engine...
  • Page 2: Table Of Contents

    TABLE OF CONTENTS Before Using the Monitor Introduction ...........3 Safety Information .
  • Page 3: Before Using The Monitor

    Women’s Advanced Automatic Blood Pressure Monitor is intended for home use. While the Omron Elite 7300W is designed for women, it has also been clinically proven accurate for all adults, regardless of gender. So you can be assured that this product can be used by men and women.
  • Page 4: Safety Information

    SAFETY INFORMATION To assure the correct use of the product basic safety measures should always be followed including the warnings and cautions listed in this instruction manual. SAFETY SYMBOLS USED IN THIS INSTRUCTION MANUAL Indicates a potentially hazardous situation which, if not avoided, could result in death or WARNING serious injury.
  • Page 5 Do not use a cellular phone near the device. It may result in an operational failure. Use only Omron authorized parts and accessories. Parts and accessories not approved for use with the device may damage the unit. Use only 1.5V alkaline batteries with this device.
  • Page 6: Care And Maintenance

    Do not submerge the device or any of the components in water. Store the device and the components in a clean, safe location. Changes or modification not approved by Omron Healthcare will void the user warranty. Do not disassemble or attempt to repair the unit or components.
  • Page 7: Before Taking A Measurement

    BEFORE TAKING A MEASUREMENT To ensure a reliable reading follow these recommendations: 1. Avoid eating, drinking alcohol, smoking, exercising, and bathing for 30 minutes before taking a measurement. Rest for at least 15 minutes before taking the measurement. 2. Stress raises blood pressure. Avoid taking measurements during stressful times.
  • Page 8: Operating Instructions

    Operating Instructions KNOW YOUR UNIT Main Unit: Display Air Jack Date/Time Setting Button ( ) Memory Button ( Start/Stop Button Battery Compartment Downloaded from www.Manualslib.com manuals search engine...
  • Page 9: Arm Cuffs

    (Connects to Air Jack) Standard Arm Cuff Large Arm Cuff Four “AAA” Batteries Stylish Zipper Case QUICK GUIDE Thank you for purchasing the Omron ¤ Elite 7300W IntelliSense ¤ Women s Advanced Automatic Blood Pressure Monitor. INSTRUCTION MANUAL There are two cuffs included in this unit, standard size and large size.
  • Page 10: Unit Display

    UNIT DISPLAY Systolic Blood Pressure Diastolic Blood Pressure Heartbeat Symbol/ Medication Symbol Hypertension Indicator Pulse Display Deflation Symbol Memory Symbol Date/Time Display Average Value Symbol Low Battery Indicator Guest Symbol Movement Error Symbol Irregular Heartbeat Symbol Downloaded from www.Manualslib.com manuals search engine...
  • Page 11: Display Symbols

    DISPLAY SYMBOLS IRREGULAR HEARTBEAT SYMBOL ( When the monitor detects an irregular rhythm two or more times during the measurement, the Irregular Heartbeat Symbol ( ) will appear on the display with the measurement values. ormal H ormal H An irregular heartbeat rhythm is defined as a rhythm that is more than 25% slower or Pulse 25% faster from the average rhythm...
  • Page 12: Heartbeat Symbol/Hypertension Indicator

    DISPLAY SYMBOLS HEARTBEAT SYMBOL/HYPERTENSION INDICATOR ( TAKING A MEASUREMENT The Heartbeat Symbol ( ) flashes on the display during the measurement. The Heartbeat Symbol ( ) flashes at every heartbeat. When the measurement is complete, the Heartbeat Symbol ( flashes on the display with your blood pressure and pulse rate if the reading is above 135 for the Systolic Blood Pressure value and/or 85 for the Diastolic Blood Pressure value.
  • Page 13 Self-diagnosis and treatment using measured results may be dangerous. Follow the instructions of your physician or licensed healthcare provider. Omron Healthcare recommends you contact your physician if the Heartbeat Symbol ( ) flashes on the display with your measurement values.
  • Page 14: Battery Installation

    BATTERY INSTALLATION 1. Press the indicator on the battery cover and slide the cover off in the direction of the arrow. Battery Cover 2. Install 4 “AAA” size batteries so the + (positive) and – (negative) polarities match the polarities of the battery compartment as indicated.
  • Page 15 BATTERY INSTALLATION BATTERY REPLACEMENT Low Battery Indicator When the Low Battery Indicator appears on the display screen, turn the monitor off and remove all the batteries. Replace with four new batteries at the same time. WARNING If battery fluid should get in your eyes, immediately rinse with plenty of clean water.
  • Page 16: Setting The Date And Time

    SETTING THE DATE AND TIME Set the monitor to the current date and time before taking a measurement for the first time. If the date and time are not set correctly, the measurement values stored in the memory and the average values may not be correct.
  • Page 17 SETTING THE DATE AND TIME 2. SETTING THE YEAR The year can be set between 2008 and 2030. When the display reaches 2030, it will return to 2008. Press the Memory button ( ) to advance by increments of one year. Press the Date/Time Setting button ( ) to set the current year.
  • Page 18 SETTING THE DATE AND TIME 4. SETTING THE DAY Press the Memory button ( ) to advance by increments of one day. Press the Date/Time Setting button ( ) to set the current day. The hour flashes on the display. 5.
  • Page 19 SETTING THE DATE AND TIME RESETTING THE DATE AND TIME To adjust the date or time after it has been setup when you first use the unit. Start with the monitor in the off position. 1. Press and hold the Date/Time Setting button ( ). The Medication Symbol ( ) No.1 and the current setting (on or oFF) will appear on the display.
  • Page 20: Setting The Medication Reminder Alarm

    S S E E T T T T I I N N G G T T H H E E M M E E D D I I C C A A T T I I O O N N R R E E M M I I N N D D E E R R A A L L A A R R M M The Medication Reminder Alarm can be set to sound twice a day to alert the user to take a medication.
  • Page 21 S S E E T T T T I I N N G G T T H H E E M M E E D D I I C C A A T T I I O O N N R R E E M M I I N N D D E E R R A A L L A A R R M M 2.
  • Page 22 S S E E T T T T I I N N G G T T H H E E M M E E D D I I C C A A T T I I O O N N R R E E M M I I N N D D E E R R A A L L A A R R M M 4.
  • Page 23 S S E E T T T T I I N N G G T T H H E E M M E E D D I I C C A A T T I I O O N N R R E E M M I I N N D D E E R R A A L L A A R R M M 6.
  • Page 24: Applying The Arm Cuff

    APPLYING THE ARM CUFF CAUTION Read all of the information in the instruction manual and any other literature in the box before operating the unit. CAUTION This device is intended for use in measuring blood pressure and pulse rate in the adult population. Do not use this device on infants or persons who cannot express their intentions.
  • Page 25: Applying The Cuff On The Left Arm

    APPLYING THE ARM CUFF 2. Fit the looped Cuff Guide on your upper arm. 3. Cuff Guide shows your correct cuff. Use the cuff with same colored sticker. Orange Use the Standard Cuff Use the Large Cuff Purple APPLYING THE CUFF ON THE LEFT ARM 1.
  • Page 26 APPLYING THE ARM CUFF 2. Remove tight-fitting clothing from your upper left arm. 3. Apply the cuff to your left upper arm so the blue arrow is centered on the inside of your arm and aligned with your middle finger. The air tube runs down the inside of your arm.
  • Page 27 APPLYING THE ARM CUFF APPLYING THE CUFF ON THE RIGHT ARM When taking a measurement using the right arm use this instruction for Step 3 on page 26. Apply the cuff to your right upper arm so the blue arrow and the air tube runs along the inside of your elbow.
  • Page 28: Taking A Measurement

    TAKING A MEASUREMENT 1. Sit in a chair with your feet flat on the floor. Place your left arm on a table so the cuff is level with your heart. 2. Press the START/STOP button. All symbols appear on the display. The cuff starts to inflate automatically.
  • Page 29 TAKING A MEASUREMENT 3. When the measurement is complete, the arm cuff completely deflates. Your blood pressure and pulse rate are displayed. 4. Press the START/STOP button to turn the monitor off. NOTE: The monitor will automatically turn off after two minutes. Downloaded from www.Manualslib.com manuals search engine...
  • Page 30: Using The Guest Mode

    TAKING A MEASUREMENT USING THE GUEST MODE The monitor is designed to take measurements and store the measurement values in the memory for one person. The monitor can also be used to take a single measurement for other persons using the GUEST Mode.
  • Page 31: Using The Memory Function

    USING THE MEMORY FUNCTION Every time you complete a measurement the monitor stores the blood pressure and pulse rate in the memory. The monitor automatically stores up to 84 sets of measurement values (blood pressure and pulse rate). When 84 sets of measurement values are stored, the oldest record is deleted to save the most recent values.
  • Page 32 USING THE MEMORY FUNCTION 2. Press the Memory button ( ) to display the most recent set of measurement values on the screen. The values are displayed from the most recent to the oldest. NOTE: The date and time are alternately displayed with the measurement values.
  • Page 33: To Delete All Values Stored In The Memory

    USING THE MEMORY FUNCTION TO DELETE ALL VALUES STORED IN THE MEMORY You cannot partially delete values stored in the memory. 1. Press the Memory button ( ) to turn the monitor on. 2. Press the Memory button ( again. While holding it down, press the START/STOP button together for more than 5...
  • Page 34: Care And Maintenance

    Care and Maintenance CARE AND MAINTENANCE To keep your digital blood pressure monitor in the best condition and protect the unit from damage, follow the directions listed below: Keep the monitor in the Stylish Zipper Case when not in use. Do not forcefully bend the arm cuff or air tube.
  • Page 35 CARE AND MAINTENANCE Use the unit consistent with the instruction provided in this manual. CAUTION Changes or modification not approved by Omron Healthcare will void the user warranty. Do not disassemble or attempt to repair the unit or components. CAUTION Use only Omron authorized parts and accessories.
  • Page 36: Error Indicators And Troubleshooting Tips

    Take another measurement and remain still until the measurement is complete. Air plug is not connected. Contact your OMRON A malfunction has distributor or Customer Services occured. as mentioned on the package. Replace the four batteries. Batteries are worn Refer to “Battery Installation.”...
  • Page 37: Troubleshooting Tips

    ERROR INDICATORS AND TROUBLESHOOTING TIPS TROUBLESHOOTING TIPS PROBLEM CAUSES AND SOLUTIONS No power. Replace all four batteries with new ones. No display appears on the unit. Check the battery installation for proper placement of the battery polarities. Blood pressure varies constantly. Many factors including stress, time of day, and how you wrap the cuff, Measurement values appear...
  • Page 38: Fcc Statement

    FCC STATEMENT NOTE: POTENTIAL FOR RADIO/TELEVISION INTERFERENCE (for U.S.A. only) This product has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.
  • Page 39: Warranty

    Repair or replacement is our only responsibility and your only remedy under the above warranties. To obtain warranty service contact Omron Healthcare for the address of the repair location. Shipping instructions and repair information is available by calling 1-800-634-4350 or visit our website at www.omronhealthcare.com.
  • Page 40: Specifications

    SPECIFICATIONS Model: Elite 7300W Display: LCD Digital Display Measurement Range: Pressure: 0 to 299 mmHg, Pulse: 40 to 180/min. Accuracy/Calibration: Pressure: ±3mmHg or 2% of reading Pulse: ±5% of reading Inflation: Automatic by electric pump Deflation: Automatic rapid deflation pressure...
  • Page 41 SPECIFICATIONS Memory: Up to 84 readings Contents: Main Unit, Standard and Large Arm Cuffs, Instruction Manual, 4 “AAA” batteries, Stylish Zipper Case, Quick Guide, Warranty Card and Cuff Guide UPC Code: 0 73796 73000 0 NOTE: These specifications are subject to change without notice. Downloaded from www.Manualslib.com manuals search engine...
  • Page 42 Manufactured by OMRON HEALTHCARE Made in China Distributed by: OMRON HEALTHCARE, INC. 1200 Lakeside Drive Bannockburn, Illinois 60015 www.omronhealthcare.com Copyright © 2007 Omron Healthcare, Inc. Downloaded from www.Manualslib.com manuals search engine...

Table of Contents