Electrical connection

All electrical work should be carried out
by a suitably qualified and competent
person in strict accordance with current
local and national safety regulations.
Connection must be made via a
switched socket. This will make it easier
for service technicians should the
appliance need to be repaired. The
electrical socket must be easily
accessible after installation.
Danger of injury!
Miele cannot be held liable for
unauthorised installation,
maintenance and repair work as this
can be dangerous to users.
Miele cannot be held liable for
damage or injury caused by incorrect
installation, maintenance or repair
work, or by an inadequate or faulty
earthing system (e.g. electric shock).
If the plug has been removed or the
connection cable is not supplied with
a plug, the CombiSet must be
connected to the mains supply by a
suitably qualified electrician.
If the appliance is to be hard-wired,
an additional means of
disconnection must be provided for
all poles in accordance with the
wiring rules. When switched off,
there must be an all-pole contact
gap of at least 3 mm in the switch
(including switch, fuses and relays).
Connection data is shown on the
data plate. It must match the mains
electrical supply.
After installation, ensure that all
electrical components are shielded
and cannot be accessed by users.
52
Total power output
See data plate.
Connection
AC 230 V, 50 Hz
The voltage and rated load are given on
the data plate. Please ensure these
match the household mains supply.
Residual current device
For extra safety, it is advisable to
protect the appliance with a suitable
residual current device (RCD) with a trip
range of 30 mA.
WARNING
THIS APPLIANCE MUST BE
EARTHED