3. Management with Web browser software
3.1 Configuring and controlling the projector via a web browser (continued)
The Alert Items are shown below.
Setting Item
Alarm Time
SNMP Trap
Send Mail
Mail Subject
Mail Text
Click the [Apply] button to save the settings.
NOTE
• The Filter Error e-mail is triggered based on the FILTER MESSAGE
settings in the OPTION>SERVICE submenu which defines the when the filter
message will display on the projector screen. The e-mail will be sent when the
filter timer exceeds 2000, 5000 or 10000 hours based on this configuration.
Notification e-mails will not be sent if the FILTER MESSAGE is set to OFF.
(OPTION menu in the User's Manual (detailed) – Operating Guide)
• Lamp Time Alarm is defined as a threshold for e-mail notification (reminder)
of the lamp timer. When the lamp hour exceeds the configured threshold, the
e-mail will be sent out.
• Filter Time Alarm is defined as a threshold for e-mail notification (reminder)
of the filter timer. When the filter hour exceeds this threshold, the e-mail will be
sent out.
20
Configures the time to alert.
(Only Lamp Time Alarm and Filter Time Alarm.)
Click the [Enable] check box to enable SNMP Trap alerts.
Click the [Enable] check box to enable e-mail alerts.
(Except Cold Start and Authentication Failure.)
Configures the subject line of the e-mail to be sent.
The length of the subject line can be up to 100 alphanumeric
characters.
(Except Cold Start and Authentication Failure.)
Configures the text of the e-mail to be sent.
The length of the text can be up to 1024 alphanumeric
characters.
(Except Cold Start and Authentication Failure.)
Description