Error Code Check - Toshiba PORTEGE M300 Maintenance Manual

Hide thumbs Also See for PORTEGE M300:
Table of Contents

Advertisement

2 Troubleshooting Procedures
Procedure 2

Error Code Check

If the power supply microprocessor detects a malfunction, the DC IN icon blinks orange. The
blink pattern indicates an error as shown below.
Start
Error code (8 bit)
"1"
"0"
Interval between data bits
The error code begins with the least significant digit.
Example: Error code = 12h (Error codes are given in hexadecimal format.)
Start
PORTEGE M300 Maintenance Manual (960-504)
2.3 Power Supply Troubleshooting
Off for 2 seconds
On for one second
On for a half second
Off for a half second
2-9

Advertisement

Table of Contents
loading

Table of Contents