8.4.

Automatic Operation

• Automatic operation can be set using remote control.
• This operation starts to operate with indoor fan at SLo speed for 25 seconds to judge the intake air temperature.
• After judged the temperature, the operation mode is determined by referring to the below standard.
• Then, the unit start to operate at determined operation mode, until it is switched off using remote control, with the setting
temperature as shown in below table.
• Operation mode will be determine again for judgement after 1 hour of operation, if the room temperature reaches to set
temperature and compressor off time is over 7 minutes 30 seconds continuously.
The present operation mode will be continued, if the room temperature does not reach to set temperature (Compressor keeps running)
eventhough after 1 hour from automatic operation mode started.
Present
Mode
Cooling
Soft Dry
Heating
• Automatic Set Temperature
For each operation, set temperature will automatically set as shown below.
• The setting temperature for all the operations can be changed one level up or one level down from the standard temperature
as shown in below table by pressing on the temperature up or temperature down button at remote control.
Judgement
23°C
Cooling
Heating
20°C
Soft Dry
Heating
Cooling
25°C
Heating
Operation
Cooling
Soft Dry
Heating
CS-W7DKE CU-W7DKE / CS-W9DKE CU-W9DKE / CS-W12DKE CU-W12DKE
Next Mode
Cooling
Soft Dry
O
(Judgement:
Not Applicable
23°C & Above)
Not Applicable
(Judgement:
20°C & Above)
O
(Judgement:
Not Applicable
25°C & Above)
Hi
(Standard)
(+2°C)
(±0°C)
27°C
25°C
24°C
22°C
23°C
21°C
23
Heating
O
(Judgement:
Below 23°C)
O
O
(Judgement:
Below 20°C)
O
(Judgement:
Below 25°C)
Lo
(-2°C)
23°C
20°C
19°C