Panasonic CS-W7DKE Service Manual page 36

Table of Contents

Advertisement

CS-W7DKE CU-W7DKE / CS-W9DKE CU-W9DKE / CS-W12DKE CU-W12DKE
(Heating Operation condition)
• When the Quiet Mode is set at the remote control, Quiet Mode LED illuminates. The sound level will reduce either around
2 dB (Lo) or 3 dB (Hi, Me), against the present sound level operation.
• Quiet setting of fan speed rpm refer to Indoor Fan Speed Control.
• Manual Fan Speed:-
− Rpm control during Lo, Me & Hi Cool
• Auto Fan Speed:-
− Rpm control depends on the piping air temperature sensor of Indoor heat exchanger
• Quiet operation stops when:-
− Quiet button is pressed again.
− Powerful button is pressed.
− Stopped by OFF/ON operation button.
− Timer OFF activates.