FM ALIGNMENT PROCEDURE SET BAND SWITCH TO RADIO MANUAL. VOLUME AT MINTMUM.BAND SW. IM"FM"POSITION. CONNECT OUTPUT CONNECT INPUT SIGNAL SET RADIO STEP OF TEST OF TEST MARRER ADJUST ADJUST FOR DIAL TO EQUIPMENT EQUIPMENT FREQUENCY FM IF SWEEP FOR MAX FM IF SWEEP GENESCOPE TO SYMMETRICAL...
Page 6
AM/FM RADIO SUPPLY VOLTAGR: AC230V50HZ STANDARD POWER OUTPUT: 50mw 1OF2 MODULATION :1KHZ 30% SPEAKER IMPEDANCE: REV:1 Measuringitems Condion Unit Normal Limit Low End ±10 Tuning Frequency Range High End ±20 1650 1650 Intermediate Frequency ±5 600KHz Max Sensitivity 1000KHz 1400KHz 600KHz •20dB Quieting S/N Sensitivity 1000KHz...
Page 7
AM/FM RADIO SUPPLY VOLTAGR: AC230V50HZ STANDARD POWER OUTPUT: 50mw 2OF2 MODULATION :1KHZ 22.5KHz SPEAKER IMPEDANCE: REV:1 Measuringitems Condion Unit Normal Limit Tuning Frequency Range Low End 87,5 ±0.5 87.5 High End 108,25 ±0.5 108.5 Intermediate Frequency ±0.35 10.75 10,7 90MHz Max Sensitivity 98MHz 106MHz...