Set Wired Zone Response Speed; Set Related Zone - Focus ST-IIIB User Manual

Hide thumbs Also See for ST-IIIB:
Table of Contents

Advertisement

User manual
10K
N/C wiring diagram
Example: set zone 35 as N/O loop type
Press[*] for 3 seconds
*
Please enter the zone
number to modify
Press confirm key to save,
Pressback key to exit.
3
#
6.6.4 set wired zone response speed(factory default is 500 millisecond)
Press[*] for 3 seconds
Enter password
*
Please enter the zone
numbEr to modify
Press confirm key to save,
Pressback key to exit.
2
#
Note: Normall the detector s response speed is 500 millisecond, high speed
response detector like vibration detector is 10 millisecond
6.6.5 set related zone: zone 1+zone 2+related time+mode
The options as belows
0>disable related zone mode
1>EXIT-ENTRANCE dual trigger mode: trigger zone 1 or 2 seperately will
not trigger alarming. Trigger zone 1 first, then during the period of related
time trigger zone 2, then both zone 1 and 2 trigger alarm.Trigger zone 2
first, then trigger zone 1 will not trigger alarm.
NC
Z
C
EOL loop
Enter password
0
NO
N/O wiring diagram
0
1
2
3
4
5
3
#
1
2
3
4
4
0
#
Z
10K
C
EOL loop
5
#
6 #
Please choose loop type:
1.EOL 2.N/C, 3.N/O
Press confirm key to save,
Pressback key to exit.
6 #
5
#
Please choose loop
response speed: 1. 500ms,
Press confirm key to save,
Pressback key to exit.
3 #
4 #
2. 10ms
29