3.2

Basic operation

Factory default
Adminitrator password: 012345
16 User passwords, NO. 01 factory default is 1234. No. 02-16 of the user
password is blank and can not enter the user setting untill user set the
password.
Disarm: User password[1234]+DISARM
Home arm: Home arm key
Arm: Arm key
Event log: inquiry key
Shutdown operation: AC power-off state (
Enter system setting:
Enter user setting:
Zone inspection: Not insepct wired zones within one minutes of panel
power up
Password reset: Enter 000000 to enter system setting menu within one
minute of panel power up.
3.3 Flashes when phone line cut. Light on when phone line
is normal.
Icon
G G
+ +
seconds) + user password [1234]+
press and hold for more than 3 seconds+
adminstrator password [012345]+
Press and hold for more than 3 seconds+ user NO.
(01) +user password(1234)+
Meaning
GSM signal strength
Telephone line
Detector low battery
_ _
PANEL low battery
Alarm
Voice prompts
#
press and hold for more than 3
#
#
#
Icon
GSM is enabled
Enable GPRS
Meaning
Left behind
Disarm
Arm