Led Indicator Lights - Centsys A10 Installation Manual

Industrial sliding gate operator
Hide thumbs Also See for A10:
Table of Contents

Advertisement

LED Indicator Lights

LED Indicator Lights
The controller is fitted with diagnostic LED's (Light Emitting Diodes) that assist with the set-up and mainte-
nance of the gate. Table 1 provides a description and purpose of the indicator LED's. See Figure 23 and 25 for
location.
NAME
COLOUR
TRG
Red
IRB
Green
Red
FRX
PED
Red
LCK
Green
Red
SET
STATUS
Red
(During
normal
operation)
Red
STATUS
(During
programme
mode)
L1
Red
(During
normal
operation)
L1
Red
(During
programme
mode)
L2
Red
(During
normal
operation)
L2
Red
(During
programme
mode)
Table 1 LED Indicator Light Description & Purpose
ON
Signal present
Safeties clear
Signal present
Signal present
System ready to
operate
Signal present
Gate fully open
If LED2 also on,
system reset to
factory default.
System in programme
mode.
If L1 also on,
system reset to
factory default.
OFF
No signal
Safeties obstructed
No signal
No signal
System locked
No signal
Gate fully closed
1 Flash/sec - Pillar light on permanently
2 Flashes/sec - Thermal shutdown
3 Flashes/sec - Origin failure
4 Flashes/sec - Collision detector operated
5 Flashes/sec - Microprocessor reset
The number of flashes correspond to the
STATUS or COUNT value being set.
Origin diagnostic
(Changes state to indicate origin status)
Off when gate is on "CLOSED" side.
On when gate is on "OPEN" side.
The number of flashes corresponds with
the FEATURE number being selected
DOSS diagnostic
(Changes state to indicate DOSS pulses)
Page 46
REMARKS
N/A
N/A
N/A
N/A
N/A
N/A

Advertisement