Example 2 (continued):
At this moment release the TEST button to give a COUNT value of 10.
This sets the Autoclose timer to 10 seconds.
L2 will come back on, indicating that the COUNT has been updated.

Controller Features

The terminology "FEATURE 2-2" refers to Feature number 2 with a status of 2.
"FEATURE 3- COUNT" refers to Feature number 3, with a user specified COUNT
value.
Autoclose
(FEATURE 2 - STATUS)
This can be programmed ON (FEATURE 2-1) or OFF (FEATURE 2-2). The factory
default is OFF. Autoclose has the function of automatically closing a gate after a
preset Autoclose time. Autoclose is automatically enabled in Condominium or
PIRAC mode.
A gate that is stopped while opening will always autoclose. A gate that is stopped
while closing will remain where it stopped indefinitely.
The autoclose time is set in FEATURE 3-COUNT. It can be set from 1 to 255 seconds.
It is possible for the user to temporarily turn off autoclose when the Mode of
Operation is either STANDARD and REVERSING. This is done by applying an
impulse to the TRG input at the time of opening the gate, for a period of time longer
than the AUTOCLOSE OVERRIDE TIME as set in FEATURE 8-COUNT. To provide
feedback that the override signal has operated, the gate will stop opening after the
override time. The instant the impulse is removed the gate will complete its opening
cycle. The Autoclose is now off and the gate will remain open indefinitely. The next
impulse received on TRG will initiate the closing cycle and the autoclose is automati-
cally re-instated.
Modes of Operation
It is possible to select 5 different Modes of Operation: STANDARD, CONDOMINIUM,
PIRAC, REVERSING AND PLC (FEATURE 4-1 to 4-5).Only one mode can be
activated at any one time. All the modes are triggered by the contact present
between the TRG input terminal and the COM terminal.
STANDARD MODE (FEATURE 4-1) (This is the factory default mode) - A
trigger impulse will cause the gate to start moving (either open or closed
depending on its position). A second impulse while the gate is still moving will
stop the gate. A third impulse will cause the gate to reverse its direction of
travel, i.e the action is START - STOP - REVERSE.
(FEATURE 4 - STATUS)
Page 35