Automatic repositioning

If the programmer blocks due to an encoder count error
a programmer reset
, when the motor has been released
or there is a problem with the motor
the courtesy light will flash simultaneously for 2 seconds and will
then switch off for 0 seconds.
When a command has been received (after pre-flashing for 10
seconds) the door automatically moves, slowly, to the completely

dISPLAY MOdE

Using the PROG button you can access the following functions in sequence:
- memorising the status of the dip-switches;
- display the status of the command and safety devices;
- display the number of manoeuvres;
- access the "test" mode;
- setting the current sensor level.
The status of the security devices
always shown on the display.
Memorising
the
DIP-SWITCH
displaying the firmware version (e.g. "0")
The segments regarding the command status
(LED "ON" = command active) and safety status
(LED "ON" = safety device at rest) light up.
The number of manoeuvres appears on the
display. This number always remains visible until
you change the setting. Once 999999 has been
exceeded the lighting up of the decimal point on
the display equals 1 million + the six figure
number.
In the "test" mode (only activated when the motor
has stopped) it is possible to check the status of
the command and safety devices and carry out
eventual maintenance. The warning lights will
activate once, each time a "Td-TB-FTCI"
command is received. In this mode you can
activate serial line communication by using the
external program, which is to be connected to the
CSER connection via cable (fig. 13). While
communication is active dashes will appear on the
display; after 5 seconds of inactivity you will be
moved back to the "test" mode. To return to the
normal operating mode press the button again
"test" will appear, then wait for 10 seconds.
Setting the current sensor.
1 = motor consumption + 1 amp
2 = motor consumption + 2 amps
3 = motor consumption + 3 amps
, after
the warning lights and
TB
FTCI
and
are
PRESS PROG
settings
and
PRESS PROG
PRESS PROG
PRESS PROG
PRESS PROG
closed position (2 times as in the programming procedure) in order
to recover the correct position
At this point the programmer will function normally. No commands
will be accepted during repositioning but the security devices will
cut in and block all movement if they go into alarm.
• To interrupt the repositioning manoeuvre, press the "PROG"
or "TB" button.
0 sec
0 sec
5 sec
Connect the
programming device
(CSER) and activate it.
0 sec
Each time "PROG" is pressed
the number will increase (from 1
to 3).
10 seconds after the last
modification you will be automatically
moved out of the mode and the
selected values will be saved (eg. 3)
24
When the
("Td-TB-FTCI") inputs are activated
the warning and courtesy lights will light up.