Needle bar rise and needle bar height
Needle bar down position
Needle bar down position
When raised 2.4 mm
When raised 2 4 mm
Needle bar down position
Rotary hook point
Needle center
n t - ®
(Model LT2-B832-400A]
^
High l> l| •Slide the needle
k] Y
clamp all the way
Needle clamp
[Model LT2-B835-400A)
1~1.5 mm
B831 B832 B882
(1) Whenthe needle bar© isinitslowest positom, the needlepositionreferenceline"a"ofthe needle bar must bealigned
with the bottom edge of the needle bar bushing O- Loosen the set screw O' and align the needle position reference
line "a" of the needle bar with the bottom edge of the needle bar bushing O
(2) When the needle bar O is 2.4 mm above its lowest position, needle position reference line "b" of the needle bar is
aligned with the bottom edge ofthe needle bar bushing O At this time, the rotary hook point must bealigned with the
needle center.
Loosen the three set screws O. and align the rotary hook point with the needle center.
When the rotary hook point is alignedwith the needle center, confirmthat the spacer between the top of the needle eye
and rotary hook point is 1 ~ 1.5 mm.
8835 8836
(1)
When the needle bar o IS in its lowest position, the needle position reference line "a" of theneedle barisalignedwith
the bottom edge of the needle bar bushing O-
(2) When the needle bar O is 2.4 mm above its lowest position, needle position reference line "b" of the needle bar is
aligned with the bottom edgeofthe needle bar bushing O- At this time, the rotary hook point must bealigned with the
needle center.
Loosen the three set screws O. and align the rotary hook point with the needle center.
(3}
When the rotary hook point is aligned with the needle center,the space between the top of the needle eyeand rotary
hook point must be 1 ~ 1.5 mm.
Remove the set screw O- turn the needle clampset screw O. and adjust so that the space between the rotary hook
point and the lop of the needle eye is 1 ~ 1.5 mm.
• One full revolution of set screw O will raise or lower the needle clamp approx. 0.6 mm.