Powered speaker system

Advertisement

Push Select
This is an overview display that is not directly edited.
Entering the configuration menu directs the user how to properly set up and connect the system.
First Screen displayed after pushing Configure?
Use RBN112 with
Subwoofer? Yes or No
If subwoofer = No: then go to location screen
No is the default selection.
If subwoofer = Yes then: Subwoofer selection screen
Subwoofer used:
Selections
RBN Subwoofer
PVXp Sub 100 Hz
PVXp Sub 110 Hz
PVXp Sub 120 Hz
Other Sub 100 Hz
Other Sub 110 Hz
Other Sub 120 Hz
NOTE: The rotary knob must be used to scroll down to see all the choices.
If RBN Subwoofer
Connect Mixer to
RBN215 Sub Input
Connect Sub Proc
Out to 112 Input
RBN112 Proc Out
is Muted
With the mixer output (sound source) connected to the subwoofer, all of the system adjustments will be made
using the RBN Sub DSP module. The User processing choices in the RBN™112, such as the 9 band GEQ, will be
bypassed, the delay will be bypassed, and the processed output muted. Program EQ (presets), GEQ and delay
screens are all affected. The hi-pass filter on the RBN™112 woofer is unchanged from it's full range setting, be-
cause the Sub performs the crossover functions.
If PVXp Subwoofer
Connect Mixer to
RBN112 Input
Connect 112 Proc
Out to PVXp In
Set PVXp x-over
to 180 Hz

Advertisement

loading