This standard work checklist is to be used by the installer in conjuction with, not instead of, the instructions contained in this installation
manual.
Customer:
Lot/Address
Model (circle one):
LM42
LM42-SS
WARNING! Risk of Fire or Explosion! Failure to install fireplace acording to these instructions can lead to a fire or
explosion.
Fireplace Install
Verified that the chase is insulated and sealed. Section 3
Verified clearances to combustibles. Section 3
Protective hearth strips installed per manual requirements. Section 3
Fireplace is leveled and secured. Section 3
Hearth extension size/height decided. Section 7
Outside air kit installed. Section 3
Door and screen weights installed. Section Section 2
Required factory included non-combustible board is in place
Chimney Section 4 & 5
Chimney configuration complies with diagrams.
Chimney installed, locked and secured in place with proper clearance.
Chimney air kit installed.
Firestops installed.
Attic insulation shield installed.
Roof flashing installed.
Termination installed.
Shrouds Section 6
Shroud is installed properly per instructions.
Facing, Mantels & Hearth Extensions Section 7
Combustible materials not installed in non-combustible areas.
Verified all clearances meet installation manual requirements.
Mantels and wall projections comply with installation manual requirements.
Hearth extension installed per manual requirements.
Fireplace Setup Section 8
All packaging and protective materials removed.
Refractory installed correctly.
Grate is properly installed.
Manual bag and all of its contents are removed from the fireplace and given to the party
responsible for use and operation.
Hearth & Home Technologies recommends the following:
• Photographing the installation and copying this checklist for your le.
• That this checklist remain visible at all times on the replace until the installation is complete.
Comments: Further description of the issues, who is responsible (Installer/Builder/Other Trades, etc.) and corrective action needed:
Comments communicated to party responsible
ATTENTION INSTALLER:
Follow this Standard Work Checklist
__________________________ by ______________________on _________
(Builder/Gen. Contractor)
Heatilator • LM42 • Installers Manual • 4087-901 • Rev A • 04/14/16
Date Installed:
Location of Fireplace:
Installer:
Dealer/Distributor Phone #
Serial #: