The LED display will always be off when the detector is first switched

Battery Status

3.1.7
Battery status can be checked at any time by pressing and
holding down the LED On/Off button and then pressing and
immediately releasing the Noise Cancel button.
Once completed the LED display will indicate the battery status
for a period of three seconds, then revert to normal operation.

Earset Socket

3.1.8
The F3 COMPACT has an internal speaker located inside the
Main Body, however, it can also be fitted with an Earset via the
Earset Socket. The procedure for connecting the Earset is
described in section 2.3.g.
A standard humanitarian demining Earset (Earset Speaker On)
permits the F3 COMPACT's internal speaker to continue to
function even when the Earset is connected.
For tactical applications, an Earset that mutes the F3 COMPACT's
internal speaker when the Earset is connected is available (Earset
Speaker Off). The Earset Speaker Off is identified by a short length
of green tubing located at the rear of the Earset plug.
Minelab strongly recommends that an operator always wears an
* WARNING *
Earset when using the F3 COMPACT detector.
F3 COMPACT Version 2 Operations Manual