Optex HX-80N Installation Instructions Manual page 17

High mount outdoor detector
Hide thumbs Also See for HX-80N:
Table of Contents

Advertisement

-LED ON/OFF
ON
OFF
-IMMUNITY
IMMUNITY
STD
-AUX INPUT
By connecting a secondary unit (another warning sensor), you can extend the detection area
and correct false alarms. The secondary unit must have a voltage free N.C. output such as
another PIR detector or AIR detector.
<Infrared (AIR) sensors, thermal line (PIR) sensors, magnet switches, etc.>
AND
Notes>>
The alarm is only activates
if both the main unit and the
secondary unit are activated
within 60 sec.
In OR mode, a secondary
detector must be fitted. If not
fitted, the unit will generate an
alarm continuously.
-PIR AND/OR
AND
Note>>
"OR" mode is appropriate for
the sites that require more
detectability rather than false
alarm tolerance such as lighting
control and camera activation.
POSITION
ON
(Factory default)
OFF
POSITION
STD
(Factory default)
IMMUNITY
POSITION
(Factory
OR
POSITION
(Factory default)
OR
- 17 -
The LED lights when someone is detected.
The LED does not light even if someone is detected.
IMMUNITY logic is not activated.
IMMUNITY logic is activated. Use this under
harsh environment (e.g. vegetation sway).
When both the main unit and the
AND
secondary detect someone, the alarm
is activated. Choose this setting when
default)
a secondary unit is not connected.
When either the main unit or the
OR
secondary detects someone, the
alarm is activated.
AND
An alarm is output when both PIR1
and PIR2 detect an object.
An alarm is output when either PIR1
or PIR2 detects an object.
Selecting "OR" mode makes detection
range longer than "AND" mode.
Walk test to readjust the detection
OR
range is required when "OR" is
selected. Actual adjustment should be
conducted by adjusting the bracket
angle.
1
DIP switch
FUNCTION
2
DIP switch
FUNCTION
3
DIP switch
FUNCTION
4
DIP switch
FUNCTION
OR mode only
HX-80N
HX-80NAM
HX-80N
HX-80NAM
HX-80N
HX-80NAM
HX-80N
HX-80NAM

Hide quick links: