4) LED3 for SDC board error check
No. of LED3
flashes
Turn on
Nil
1
Main shaft motor lock
2
Error in phase Z
3
Error in phases A and B
4
Motor position sensor error
5
IPM error
6
Undervoltage
7
Motor reverse rotation
8
Overvoltage
9
Power interruption
10
Not used
11
+85V power system error
12
+33V power system error
13
Overheating
14
Not used
15
Communication error
Error description
Display of op-
eration panel
Dimly turn on in ordinary state
E007
Failure in revolving for 2 seconds
E303
Failure in phase Z detection
About 1.5 turns
E730
Failure in phases A and B detection
About 0.5 turns
E731
Logical error in U, V, W
E901
Error output generation from IPM
E813
Source voltage -20% or more
E733
Irregular motor revolutions
E811
Source voltage +20% or less
Display disabled
Power interruption of 40 msec or more
E903
SDC board fuse F1 blow-off
E904
SDC board fuse F2 blow-off
E905
Radiator panel of SDC board heated at
85℃ or more
E916
Failure in communication with the MAIN
board
– 69 –