Panasonic Varicam 35 Operating Manual page 107

Table of Contents

Advertisement

Item
[- NEAR END VOLT]
[- END VOLT]
[CAM DC IN SOURCE]
[CAM BATTERY
SETTINGS]
[- FULL VOLT]
[- NEAR END VOLT]
[- END VOLT]
[END ALARM]
[FAN]
[FAN SPEED]
[GENLOCK]
[GENLOCK MODE]
[H PHASE COARSE]
[H PHASE FINE]
[SENSOR SYNCHRO]
[CONTROL DISPLAY]
[BRIGHTNESS]
[COLOR LEVEL]
Chapter 10 Menu Operations — Menu list
Sets the near end voltage when the remaining charge of the battery for the V-RAW recorder is detected
with the voltage level.
Displayed only when the V-RAW recorder is connected.
[11.0V] - [15.0V] (0.1 V step)
f Factory setting: [13.2V]
Sets the end voltage when the remaining charge of the battery for the V-RAW recorder is detected with the
voltage level.
Displayed only when the V-RAW recorder is connected.
[11.0V] - [15.0V] (0.1 V step)
f Factory setting: [12.5V]
Sets the type of the external power source input to the <DC IN> terminal of the camera extension module
when the camera module and the recording module is separated and they are used connected with an
extension cable.
Displayed only when the extension module is attached.
[DC POWER SUPPLY]: Selected when connecting an AC adaptor. In this case, the remaining battery
charge level is not displayed.
[BATTERY]: Selected when a battery is connected to the <DC IN> terminal. The remaining battery level of
the camera extension module is detected in accordance with [CAM BATT FULL], [CAM BATT NEAR END],
or [CAM BATT END].
f Factory setting: [DC POWER SUPPLY]
(Display only)
Sets the voltage to display the remaining battery level of the camera extension module as full when the
camera module and the recording module is separated and used by connecting them with a extension
cable.
Displayed only when the extension module is attached.
[13.0V] - [17.0V] (0.1 V step)
f Factory setting: [15.5V]
Sets the near end voltage for the remaining battery level of the camera extension module when the
camera module and the recording module is separated and used by connecting them with a extension
cable.
Displayed only when the extension module is attached.
[11.0V] - [15.0V] (0.1 V step)
f The maximum value is the value set in [FULL Volt]. (However, the maximum is [15.0V])
f Factory setting: [13.2V]
Sets the end voltage for the remaining battery level of the camera extension module when the camera
module and the recording module is separated and used by connecting them with a extension cable.
Displayed only when the extension module is attached.
[11.0V] - [15.0V] (0.1 V step)
f The maximum value is the value set in [NEAR END Volt].
f Factory setting: [12.5V]
Sets whether to sound an alarm at battery remaining charge level end.
[ON], [OFF]
f Factory setting: [ON]
Select the rotation speed of the fan.
[REC AUTO]: The rotation speed is lowered simultaneously with start of recording. However, the fan will
rotate in maximum speed when it reaches the specified temperature.
[MATCH CODEC]: The fan will operate in rotation speed appropriate for each in accordance with [MAIN
CODEC].
[ALWAYS FULL]: The fan will always rotate at the maximum speed.
f Factory setting: [REC AUTO]
Switches the synchronization signal of the camera signal.
[INT]: Synchronizes to the internal standard signal.
[EXT]: Synchronizes to the entered external standard signal.
f Factory setting: [INT]
Roughly adjusts to match horizontal synchronization phase when building a system.
[−100]...[100]
f Factory setting: [0]
Minutely adjusts to match horizontal synchronization phase when building a system.
[−100]...[100]
f Factory setting: [0]
Sets the operation to synchronize the sensors for creating 3D video, etc.
[MASTER]: Outputs with the synchronization signal superimposed to the output from the <SDI OUT1>
terminal.
[SLAVE]: Shoots with the sensor synchronized to the synchronization signal from the master. It is
necessary to set [GENLOCK MODE] to [EXT] to perform slave operation. The synchronization signal is
output from <SDI OUT1>.
[OFF]: Output or receiving of the synchronization signal is not performed.
f Factory setting: [OFF]
Adjusts the brightness of the control panel.
[−15]...[15]
f Factory setting: [0]
Adjusts the color levels of the control panel.
[−15]...[15]
f Factory setting: [0]
– 107 –
Description of settings