Leds; Cabling; Expresspci Fc 3321; Expresspci Fc 3322 - ATTO Technology ExpressPCI FC 3321, FC 3322, FC 3342 Installation And Operation Manual

2-gigabit host adapter
Hide thumbs Also See for ExpressPCI FC 3321, FC 3322, FC 3342:
Table of Contents

Advertisement

ExpressPCI FC 3321

The ATTO ExpressPCI FC 3321 has two SFF
duplex LC optical connectors and uses a short
wave laser. A multi-mode cable must be used with
short wave lasers. For best performance you
should use 50 micron multi-mode optical cables.
Cable length should be no more than 500 meters.

ExpressPCI FC 3322

The ATTO ExpressPCI FC 3322 has two
pluggable SFP LC optical connectors and uses a
short wave laser. A multi-mode cable must be
used with short wave lasers. For best performance
you should use 50 micron multi-mode optical
cables. Cable length should be no more than 500
meters.

ExpressPCI FC 3342

The ATTO ExpressPCI FC 3342 has four
pluggable SFP LC optical connectors and uses a
short wave laser. A multi-mode cable must be
used with short wave lasers. For best performance
Exhibit 3-2 ExpressPCI FC 3321 bracket and board
ExpressPCI FC 3321 bracket and board
FC link activity/fault LED
Port 1, SFF
Port 0, SFF
optical connectors
you should use 50 micron multi-mode optical
cables. Cable length should be no more than 500
meters.

LEDs

Dual-purpose LEDs, one per port and visible
through the bracket, indicate activity on the Fibre
Channel link. A blinking green LED shows
activity on that channel; a yellow LED shows a
fault condition.
Link
Activity
Off Green blinking Yellow

Cabling

Fibre Channel technology offers a variety of
cabling options including standard copper,
equalized copper and fiber optic, depending on
the requirements of your environment.
FC Controller
PCI bus edge connector
Fault
8