Read First: Safety Information
Understand and follow operating instructions carefully.
Use the meter, test leads and all accessories only as
specified in this manual; otherwise, the protection
Digital Multimeter
provided by the meter can be impaired.
Instruction Manual
WARNING
To avoid possible electric shock, personal injury or
death, follow these guidelines:
• Do not use if meter appears damaged. Visually inspect
the meter to ensure case and jaws are not cracked.
• Inspect and replace test leads if insulation is damaged,
metal is exposed, or probes are cracked. Pay particular
attention to the insulation surrounding the connectors.
• Always ensure the meter, test leads and all accessories
meet or exceed the measurement category required
in the working environment. (i.e. CAT rating)
• Note that the measurement category and voltage
rating of combinations of the meter, the test leads,
and the accessories is the lowest of the individual
components.
• Do not use meter if it operates abnormally as
protection maybe impaired.
• Do not use during electrical storms or in wet weather.
• Do not use around explosive gas, dust, vapor,
amperage or in damp or wet environments.
• Do not apply more than the rated voltage to the meter.
• Remove the test leads from the input jacks before
measuring current.
• Replace battery as soon as battery indicator
appears to avoid false readings.
• Remove the test leads from the meter prior to
removing battery cover.
• Do not use without the battery and battery cover
properly installed.
• Do not attempt to repair this unit as it has no user-
serviceable parts.
• Use the proper terminals, functions and range for
your measurements.
• Never ground yourself when taking electrical
measurements.
• Connect the black common lead to ground or neutral
before applying the red test lead to potential voltage.
Disconnect the red test lead from the voltage first.
• Keep fingers behind the guard rings of the probe tips.
• Voltages exceeding 30VAC or 60VDC pose a shock
hazard so use caution.
CAUTION
Ranges & Accuracies
To protect yourself, think "Safety First":
• Comply with local and national safety codes.
AC Converter: 61-340 model is averaging sensing, rms calibrated; 61-342 model is true rms sensing.
• Use appropriate personal protective equipment such
Accuracy: Accuracy is specified as +/-(a percentage of the reading + a fixed amount) at 23°C±5°C (73.4°F ± 9°F), less than 75% relative humidity.
as face shields, insulating gloves, insulating boots,
Temperature Coefficient: 0.1 times the applicable accuracy specification from 32°F to 64°F and 82°F to 122°F (0°C to 18°C ; 28°C to 50°C).
and/or insulating mats.
• Before each use:
- Perform a continuity test by touching the test leads
Function
together to verify the functionality of the battery
and test leads.
DC Voltage
- Use the 3 Point Safety Method. (1) Verify meter
operation by measuring a known voltage. (2) Apply
AC Voltage
meter to circuit under test. (3) Return to the known
live voltage again to ensure proper operation.
(40~400Hz)
• Always work with a partner.
Symbols on the Unit
DC Current
Risk of Danger. Important Information. See
Manual.
AC Current
Hazardous voltage. Risk of electrical shock.
(40~400Hz)
~
Application around and removal from Hazard-
ous Live conductors is permitted.
AC (Alternating Current)
DC (Direct Current)
Resistance
Earth Ground
Measurement Category II applies to test and
measuring circuits connected directly to utiliza-
CAT II
tion points (socket outlets and similar points)
Capacitance*
of the low-voltage MAINS installation
Measurement Category III applies to measuring
CAT III
circuits connected to the distribution part of the
building's low-voltage MAINS installation
Frequency
10.00/100.0/1.000k/10.00k/100.0k/1.000M/10.00M Hz
Measurement Category IV applies to test and
CAT IV
measuring circuits connected at the source of
Duty Cycle
the building's low-voltage MAINS installation
Diode CheckTest current : (1±0.6) mA and then open circuit voltage is 2.5VDC typical.
Test Leads
Continuity
The beeper turns on <25Ω and turns off at >120Ω.
CAT IV 600V
CAT II 1000V
CAT III 1000V
Temperature**
Guard ring
*Accuracy not available for <10nF capacitance. **Accuracy is stated for meter only. Thermocouple accuracy adds another ±2.5% to reading.
Input Impedance : 10MΩ for VAC & VDC.
Range & Resolution
Accuracy
400.0m/4.000/40.00/400.0 V
±(0.5%+5)
600.0V
±(1.0%+3)
400.0m/4.000/40.00/400.0/600 V
±(1.5%+5)
400.0/4000 µA ; 40.00/400.0 mA
±(0.5%+5)
4.000/10.00 A
±(1.5%+5)
400.0/4000 µA
±(1.5%+5)
40.00/400.0 mA
±(2.0%+5)
4.000/10.00 A
±(2.5%+5)
400.0Ω
±(1.2%+5)
4.000k/40.00k/400.0k Ω
±(1.0%+2)
4.000MΩ
±(1.2%+2)
40.00MΩ
±(2.0%+5)
40.00nF
±(3.0%+10)
400.0n/4.000µ/40.00µ F
±(3.0%+5)
400.0µ/4000µ F
±(20%+5)
±(0.1%+3)
Sensitivity: <1MHz: 0.7Vrms ; >1MHz: 5Vrms
0.1 - 99.9%
±(2.5%+5) (<10kHz)
-58~1500°F
±(3.0%+5)
-50~800°C
±(3.0%+3)
CF > 2, add ±1.0% to accuracy.
AC Voltage (V
Overload Protection
900VDC
750VAC rms
500mA/600V Fast Fuse
10A/1000V Fast Fuse
500mA/600V Fast Fuse
10A/1000V Fast Fuse
DC Voltage (V )
DC
600V DC/AC rms
600V DC/AC rms
DC
600V DC/AC rms
600V DC/AC rms
600V DC/AC rms
~
)
Toggle for
Frequency
(>20% of
range)

Advertisement

loading

Summary of Contents for IDEAL 61-340

  • Page 1 #61-342 • Comply with local and national safety codes. Read First: Safety Information AC Converter: 61-340 model is averaging sensing, rms calibrated; 61-342 model is true rms sensing. Toggle for • Use appropriate personal protective equipment such Understand and follow operating instructions carefully.
  • Page 2: Resistance (Ω)

    600 volts potential. depress to exit Safety Complies with UL/IEC/EN 61010-1, °C an IDEAL product, including but not limited to • Duty cycle: 15sec ON / 15min OFF for mode. Certification: 61010-031, Cat III-600V implied warranties of merchantability and fitness for 10A MAX Ω...
  • Page 3 • Los voltajes superiores a 30 VCA o 60 VCD representan Lea Primero: Información de Seguridad Conversor de CA: El modelo 61-340 es con sensado de promedio, calibrado en valor eficaz; el modelo 61-342 es con sensado de valor eficaz verdadero. un riesgo de descarga eléctrica, así que tenga Conmute Entienda y siga las instrucciones de operación...
  • Page 4: Resistencia (Ω)

    Rojo voltaje de operación Negro compra. Durante este período de garantía, IDEAL Negro Altitud: 6561.7 pies. (2000 m) Rojo Desconecte la alimentación, inserte el instrumento INDUSTRIES, INC.
  • Page 5 Pour vous protéger, ayez le réflexe « la sécurité d’abord ». Convertisseur c.a. : Le modèle 61-340 assure une détection par calcul de moyenne, le modèle 61-342 étalonné avec des valeurs efficaces réelles assure une véritable détection avec des valeurs efficaces #61-342 boîtier et sa pince ne sont pas fissurés...
  • Page 6: Spécifications

    “OL” est affiché. appuyer pour renseignements concernant l’entretien-dépannage, Polarité : Automatique (pas libérer l’affichage. se mettre en rapport avec IDEAL INDUSTRIES, INC. Basculer d’indication de polarité Au 1-877-201-9005 ou visitez notre site web www. pour AC Mini/Maxi positive) ; Signe moins (-) idealindustries.com...

This manual is also suitable for:

61-342