Code
Device timeout
An image synchronous signal from the Main
E315-
0530
Controller PCB to the Reader is not received within
30 seconds.
Device abnormal completion
E315-
An abnormal signal from the Main Controller PCB
0531
to the Reader is detected.
Device timeout
E315-
An image synchronous signal from the Main
0540
Controller PCB to the Reader is not received within
30 seconds.
Device abnormal completion
E315-
An abnormal signal from the Main Controller PCB
0541
to the Reader is detected.
E315-
Device timeout
0550
An image synchronous signal from the Main
12
Description
Remedy
1. Turn OFF and then
ON the main power.
2. Check the connection
of the Main Controller
PCB (including the flat
cable).
3. Replace the flat
cable.
4. Replace the Main
Controller PCB (PCB2).
1. Turn OFF and then
ON the main power.
2. Check the connection
of the Main Controller
PCB (including the flat
cable).
3. Replace the flat
cable.
4. Replace the Main
Controller PCB (PCB2).
1. Turn OFF and then
ON the main power.
2. Check the connection
of the Main Controller
PCB (including the flat
cable).
3. Replace the flat
cable.
4. Replace the Main
Controller PCB (PCB2).
1. Turn OFF and then
ON the main power.
2. Check the connection
of the Main Controller
PCB (including the flat
cable).
3. Replace the flat
cable.
4. Replace the Main
Controller PCB (PCB2).
1. Turn OFF and then
ON the main power.