Toshiba BU302MG Instruction Manual page 80

Hide thumbs Also See for BU302MG:
Table of Contents

Advertisement

● Note
In Bulk function, you may want to set "Continuous" to "AcquisitionMode" register.
You can set "MultiFrame", but acquisition frame number is limited by "AcquisitionFrameCount.
AcquisitionMode = MultiFrame
AcquisitionFrameCount = 2
TriggerMode = On
TriggerSequence = 6
TriggerAdditionalParameter = 3
Start
Acquisition
Command
The trigger can be input in arbitrary timing.
Trigger
VD
Exposure
Frame 1
*Exposure overlaps sensor readout.
*Exposure time is determined by ExposureTime setting.
USB Bus
Copyright © 2016 TOSHIBA TELI CORPORATION, All rights reserved.
AcquisitionFrameRate
Frame 2
Frame 3
TriggerAdditionalParameter
Frame 1
Frame 2
AcquisitionFrameCount
Stop
This exposure is
discarded.
Stream
stops
79 / 81
http://www.toshiba-teli.co.jp/en/index.htm
Start
Counter is reset.
Frame 1
Frame 1
D4253386A