2JL/2JJ/2JG/2JD-1
Maintenance
item No.
U465
U467
1-3-86
Downloaded from
www.Manualslib.com
Data reference for ID correction
Description
References the data related to ID correction.
Purpose
To check the corresponding data.
Method
1. Press the start key.
1. Select the item to be reference. The current setting is displayed.
Display
TCONT
XYZ (K)
XYZ (C)
XYZ (M)
XYZ (Y)
Completion
Press the stop/clear key. The screen for selecting a maintenance item No. is displayed.
Setting the color registration adjustment
Description
Sets the color registration adjustment and transfer belt speed correction. Also, determines the conditions by
which color registration correction is executed depending on the LSU temperature.
Purpose
If color variance is uneven due to a sensor failure, etc., turn this off and temporarily make a manual adjust-
ment.
Method
1. Press the start key.
2. Select the item to be set.
Display
Color Regist Adjustment
Transfer Belt Speed Adj.
Adjust Timing
Setting: color registration correction
1. Select ON or OFF.
Display
ON
OFF
2. Press the start key. The setting is set.
Setting: transfer belt speed correction
1. Select ON or OFF.
Display
ON
OFF
2. Press the start key. The setting is set.
Setting: Operating timing
1. Change the setting value using the cursor up/down keys.
Description
Conditions for execution depending on the LSU
temperature variation
2. Press the start key. The value is set.
Completion
Press the stop/clear key. The screen for selecting a maintenance item No. is displayed.
manuals search engine
Description
Description
Developing bias control value after ID correction
Data of grayscale variance (Black)
Data of grayscale variance (cyan)
Data of grayscale variance (magenta)
Data of grayscale variance (yellow)
Description
Setting the color registration correction operation
Setting the transfer belt speed correction operation
After the previous correction is executed, color registration is com-
pensated as the LSU temperature varies by the value determined.
Description
Enables the color registration correction operation.
Disables the color registration correction operation.
Description
Enables the transfer belt speed correction operation.
Disables the transfer belt speed correction operation.
Setting range
4 to 10
Initial setting
4