TO THE INSTALLER: This manual is the property of the owner and must be affixed near the boiler
TO THE OWNER: This boiler should be inspected annually by a Qualified Service Agency.
WARNING
If the information in this manual is not
followed exactly, a fire or explosion
may result causing property damage,
personal injury or loss of life.
– Do not store or use gasoline or other
flammable vapors and liquids in the
vicinity of this or any other appliance.
– WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch;
do not use any phone in your
building.
• Immediately call your gas supplier
from a neighbor's phone. Follow the
gas supplier's instructions.
• If you cannot reach your gas supplier,
call the fire department.
– Installation and service must be
performed by a qualified installer,
service agency or the gas supplier.
Service Agency
Address
Boiler Model No.
I
SER'S
NFORMATION
/MIH II
for future reference.
TO BE COMPLETED BY THE INSTALLER
Serial No.
PB HEAT, LLC
131 S. CHURCH ST • BALLY, PA 19503
M
ANUAL
/MI
G
AS
MISE EN GARDE
Négliger de suivre ces instructions à la lettre
pourrait provoquer un incendie ou une
explosion causant des dégâts matériels, des
blessures ou la mort.
– Ne pas ranger ou utiliser de la gazoline ou
d'autres liquides ou gaz inflammables à
proximité de cet appareil ou d'un autre du
même type.
– QUE FAIRE SI VOUS DÉTECTEZ UNE
ODEUR DE GAZ
• Ne pas tenter d'allumer l'appareil.
• Ne toucher à aucun interrupteur électrique ;
n'utiliser aucun appareil téléphonique dans
l'immeuble.
• Contacter immédiatement votre fournisseur
de gaz à partir du téléphone d'un voisin.
Suivre les instructions données par votre
fournisseur de gaz.
• S'il est impossible de rejoindre le
fournisseur de gaz, appeler le service
des incendies.
– L'installation et l'entretien doivent être effectués
par un installateur qualifié, une société
d'entretien ou le fournisseur de gaz.
Phone No.
Date of Installation:
B
OILERS
MI8082 R2 (11/14-5M)
Printed in U.S.A.
©2014 PB Heat, LLC. All rights reserved.

Advertisement

loading
Need help?

Need help?

Do you have a question about the MI85 SERIES and is the answer not in the manual?

Questions and answers

Summary of Contents for PB Heat MI85 SERIES

  • Page 1 TO BE COMPLETED BY THE INSTALLER Service Agency Phone No. Address Boiler Model No. Serial No. Date of Installation: PB HEAT, LLC 131 S. CHURCH ST • BALLY, PA 19503 MI8082 R2 (11/14-5M) Printed in U.S.A. ©2014 PB Heat, LLC. All rights reserved.
  • Page 2: Basic Operation

    Basic Operation WARNING Service on this boiler should be undertaken only by trained and skilled personnel from a qualified service agency. L’entretien de cette chaudière doit être effectué seulement par des employés qualifiés et d’expérience appartenant à une société d’entretien reconnue. CAUTION Should overheating occur or the gas supply fail to shut off, do not turn off or disconnect the electrical supply to the pump.
  • Page 3 5. Gas Valve. The gas valve regulates gas flow to the burners and pilot. See Figure 1. 6. Safety Relief Valve. A device which protects the boiler against excessive pressure. The safety relief valve can discharge a large amount of hot water - the installer should provide piping to discharge water near floor at a floor drain.
  • Page 4 Figure 2: Intermittent Ignition Operating Instructions...
  • Page 5 Figure 3: Intermittent Ignition Operating Instructions...
  • Page 6 Figure 4: Intermittent Ignition Sequence of Operation...
  • Page 7: User Maintenance

    User Maintenance WARNING Product Safety Information Refractory Ceramic Fiber Product This appliance contains materials made from refractory ceramic fibers (RCF). Airborne RCF, when inhaled, have been classified by the International Agency for Research on Cancer (IARC), as a possible carcinogen to humans. After the RCF materials have been exposed to temperatures above 1800°F (980°C), they can change into crystalline silica, which has been classified by the IARC as carcinogenic to humans.
  • Page 8 WARNING Service on this boiler should be undertaken only by trained and skilled personnel from a qualified service agency. Inspections should be performed at intervals specified in the Installation, Operation and Maintenance Manual and this User’s Information Manual. Maintain manuals in a legible condition. Keep boiler area clear and free of combustible materials, gasoline and other flammable vapors and liquids.
  • Page 9 7. Check main burner flames. See Figure 5. The flames should have clearly defined inner cones approximately 1-1/2" (40 mm) high and should have a very sharp blue color characteristic. If the flame is yellow and lazy, follow instructions TO TURN OFF GAS TO APPLIANCE (see Figures 2 &...