PB Heat Series GM User's Information Manual

PB Heat Series GM User's Information Manual

Pb heat series gm gas boilers
Hide thumbs Also See for Series GM:

Advertisement

Quick Links

U
S
ERIES
TO THE INSTALLER: This manual is the property of the owner and must be affixed near the boiler for
TO THE OWNER: This boiler should be inspected annually by a Qualified Service Agency.
Service Agency
Address
Boiler Model No. GM-
I
SER'S
NFORMATION
GM G
future reference.
If the information in this manual is not followed
exactly, a fire or explosion may result causing
property damage, personal injury or loss of life.
– Do not store or use gasoline or other flammable vapors
and liquids in the vicinity of this or any other appliance.
– WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch;
do not use any phone in your building.
• Immediately call your gas supplier from a neighbor's
phone. Follow the gas supplier's instructions.
• If you cannot reach your gas supplier, call the fire
department.
– Installation and service must be performed by a qualified
installer, service agency or the gas supplier.
TO BE COMPLETED BY THE INSTALLER
PB HEAT, LLC
PO BOX 447 • NEW BERLINVILLE, PA 19545-0447
AS
W W A A R R N N I I N N G G
Serial No.
M
ANUAL
B
OILERS
Phone No.
Date of Installation:
GM8070 R3 (10/06-1M)
Printed in U.S.A.

Advertisement

loading
Need help?

Need help?

Do you have a question about the Series GM and is the answer not in the manual?

Questions and answers

Summary of Contents for PB Heat Series GM

  • Page 1 TO BE COMPLETED BY THE INSTALLER Service Agency Phone No. Address Boiler Model No. GM- Serial No. Date of Installation: PB HEAT, LLC PO BOX 447 • NEW BERLINVILLE, PA 19545-0447 GM8070 R3 (10/06-1M) Printed in U.S.A.
  • Page 2: Basic Operation

    Basic Operation WARNING Service on this boiler should be undertaken only by trained and skilled personnel from a qualified service agency. CAUTION Should overheating occur or the gas supply fail to shut off, do not turn off or disconnect the electrical supply to the pump.
  • Page 3 Figure 1: Control Locations B. Operating Instructions: Instructions to place the boiler in operation and to turn off the boiler are shown on the Lighting Instructions Label posted on the inside of the front jacket panel of the boiler. The instructions are also shown in Figures 2, 3 and 4. C.
  • Page 4 Note 1: On SmartValve models (boiler suffix “SV”), if pilot flame is not detected within 30 seconds, the igniter is turned off for 30 seconds, and then turned back on. If the pilot is not detected within 30 seconds, the igniter and pilot gas are turned off for 5 minutes. The sequence then resumes at Step 4a.
  • Page 5 Figure 2: Operating Instructions, SmartValve Intermittent Ignition (boiler model suffix “SV”)
  • Page 6 Figure 3: Operating Instructions, Spark Ignition (boiler model suffix “SPRK”)
  • Page 7 Figure 4: Lighting Instructions, Standing Pilot (boiler model suffix “STDG”)
  • Page 8: User Maintenance

    User Maintenance WARNING Service on this boiler should be undertaken only by trained and skilled personnel from a qualified service agency. Inspections should be performed at intervals specified in the Installation, Operation and Maintenance Manual and this User’s Information Manual. Maintain manuals in a legible condition.
  • Page 9 D. Controls (as required by control manufacturer) 1. Safety Relief Valve. Conduct try lever test as outlined in manufacturer’s instruction tag on the safety relief valve. 2. Low Water Cut-off (if used). Follow instructions provided by control manufacturer. E. General Inspection and Maintenance (Annual). For continued safe operation a qualified service agency must provide a more detailed inspection of burners, heat exchanger and vent system, and provide maintenance as specified in the Installation, Operation and Maintenance Manual.
  • Page 10 WARNING Product Safety Information Refractory Ceramic Fiber Product This appliance contains materials made from refractory ceramic fibers (RCF). Airborne RCF, when inhaled, have been classified by the International Agency for Research on Cancer (IARC), as a possible carcinogen to humans. After the RCF materials have been exposed to temperatures above 1800°F (980°C), they can change into crystalline silica, which has been classified by the IARC as carcinogenic to humans.