2/Installing Your Appliance; Electrical Connection - Brandt me1245m Instructions For Use Manual

Table of Contents

Advertisement

2/INSTALLING YOUR APPLIANCE

Tip
To be certain that you have properly installed your appliance, do not hesitate to seek advice
from a household appliance specialist.
Monophase line 220-240 V ~
16A fuse or differential
Electrical outlet
2 prong receptacle +earth
CEI Standard 60083
• ELECTRIC CONNECTION
Electrical safety must be ensured by a correct build-in. During fitting and maintenance
operations, the appliance must be unplugged from the electrical grid; fuses must be switched
off or removed.
The electrical connection should be performed before the appliance is installed in the cabinet.
Ensure that:
- the electrical installation has sufficient voltage,
- the electrical wires are in good condition
- the diameter of the wires complies with the installation requirements.
Your oven must be connected with a (standardised) power cable with 3 conductors of 1.5mm2
(1 live + 1 neutral + earth) which must be connected to a 220-240V ~ single-phase grid via the
intermediary of a 1 live + 1 neutral + earth CEI 60083 standardised power socket or via an all-
pole cut-off device or in compliance with the installation rules.
circuit breaker
supply cable
length 1.50 m approx.
Monophase 20A Counter
220-240V ~ 50Hz
Power