Clearances To Combustibles; Thermostat Installation - HAMPTON BAY GCI60 Technical Manual

Cast iron pellet insert
Hide thumbs Also See for GCI60:
Table of Contents

Advertisement

C
C
LEARANCES TO
OMBUSTIBLES
INSTALLED AS A FIREPLACE INSERT STOVE MODEL (FPI) / A INSTALLE
COMME UN MODELE SUR PIED DE POELE.
Minimum clearances to combustible materials./ Les dégagements minimums aux
matériels combustibles:
A
Sidewall to center of unit
B
Sidewall to surround panel (De la paroi à l'entoure le panneau)
C
Bottom of unit to an unshielded 12" (305 mm) mantle
(Le fond de l'unité à un manteau de cheminée non blindé)
D
Unit to top facing (protruding ¾" [19 mm])
(De l'unité au sommet du parement)
E
Unit to side facing (protruding ¾" [19 mm])
F
From door opening of unit to edge of floor protection
(De la porte ouvrant au devant de protection de plancher)
G
From side of unit to edge of floor protection
(De l'ouverture de porte pour prendre parti de protection de plancher)
Figure 4: GCI60 Clearance to Combustibles.
T
I
HERMOSTAT
NSTALLATION
Figure 5: Thermostat connection wires.
Hampton GCI60 Cast Pellet Insert Technical Manual
Installation
:
(De la paroi au centre de l'unité)
B
A
G
:
(De l'unité au côté du parement)
These dimensions are minimum clearances.
It is recommended that you ensure
C
sufficient room for servicing, routine
Combustible floors must be protected
D
cleaning and maintenance.
by a non-combustible material.
- See Owners Manual.
The unit must be installed with a minimum
Le plancher combustible doit être
E
of 6" (152 mm) of fl oor protection in front
protégé par un matériel incombustible.
- Consultez le manual.
of and to the sides of the door opening.
F
1. Install the wall thermostat (millivolt rated thermostat
recommended, or a 12/24 Volt rated thermostat set to
millivolts) in a location that is not too close to the unit
but will effectively heat the desired area.
2. Connect the Thermostat or Timer to the thermostat
wires on the unit. (Fig. 5)
If the heat in the room becomes too great, the high limit
switch may turn the stove off and the switch will have to
be manually reset. To reset the high limit switch:
-open the hopper lid
-remove plug under control panel
-use screwdriver to press down on the button on top of
the snap disk switch
24" (610 mm)
2" (51 mm)
33" (838 mm)
0" (0 mm)
0" (0 mm)
6" (152 mm)
6" (152 mm)
11