Meridian Nortel 1 Option 11C Technical Reference Manual page 445

Nortel networks network system technical reference guide
Hide thumbs Also See for Nortel Meridian 1 Option 11C:
Table of Contents

Advertisement

Table 136
Multimode and Single Mode glass optical cable requirements
Parameter
Glass Fiber Cable Length
Cable Attenuation @1300 nm
Modal Bandwidth @1300 nm
Chromatic Dispersion @1300 nm
Typical 3dB Optical Bandwidth
Table 136 lists the minimum optical requirements for Multimode and Single
Mode glass fiber optic cable used with the Option 11C.
Minimum
200
Note: The typical power budget for the glass fiber link is typically 8 dB.
The fiber link is limited to a maximum length of 3 km, even though with
many optical cables the optical power budget of 8 dB could support
greater lengths. To guarantee reliable operation a bandwidth of 150%
should be maintained. If the link is increased beyond the 3 km length the
150% margin is deteriorated possibly resulting in link malfunction under
some conditions.
Cable specifications and interfaces
Typical
1.5
500
6
180
Option 11C and 11C Mini
Page 445 of 544
Maximum
Units
3.0
km
2.0
dB/km
MHz * km
ps / nm * km
MHz * km
Technical Reference Guide

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents