Figure 10
Card slot assignment plan: Option 11C Mini Chassis Expander
Slot 10 - Meridian Mail
Mini or any IPE card
Slot 9 - Any IPE card
Slot 8 - Any IPE card
Slot 7 - Any IPE card
Provisioning conference/TDS loops
Conference loops
553-3011-100
Standard 14.00
Provisioning
t
The Conference function is provided by the NTDK20 Small System
Controller (SSC) in Option 11C, and the NTDK97 Mini System Controller
(MSC) in Option 11C Mini.
For the Option 11C, each conference loop supports 16 conferees. By default,
two conference loops are always active, more becomes active when the
expansion cabinets are equipped. Therefore the SSC supports a total of 32
conferees by itself.
Each port on a Fiber Expansion Daughterboard on the Small System
Controller supports an additional conference loop for a total of:
•
48 conferees when equipped with one Fiber Expansion Link
•
64 conferees when equipped with two Fiber Expansion Link
January 2002