Meridian Nortel 1 Option 11C Technical Reference Manual page 334

Nortel networks network system technical reference guide
Hide thumbs Also See for Nortel Meridian 1 Option 11C:
Table of Contents

Advertisement

Page 334 of 544
553-3011-100
Standard 14.00
European Digital telephones: 3110, 3310, and 3820
Note 1: All terminals must be isolated from the input winding and each
terminal must be isolated from all other terminal windings. A separate
winding is required for each terminal, and grounds must not be
connected.
Note 2: The QUT1 closet power supply source is not compatible with
Meridian digital telephones.
The AC source must be rated at 29 Vac, 700 mA isolated. The DC source
must be rated at 42 Vdc, 300 mA isolated, with current limiting output of 1
amp.