Meridian Nortel 1 Option 11C Technical Reference Manual page 206

Nortel networks network system technical reference guide
Hide thumbs Also See for Nortel Meridian 1 Option 11C:
Table of Contents

Advertisement

Page 206 of 544
Voltage
Over-voltage
Under-voltage
553-3011-100
Standard 14.00
Power supplies
The Option 11C Mini AC power supply provides +5.1, +8, +15, -15, and -
48V. -120V/-150V is selected or disabled by DIP switch settings.
There is a 1.0 second start-up delay on the +5V rail.
An OVP (Over-Voltage Protection) circuit will shut down all outputs if the
+5 V output voltage exceeds the over-voltage threshold.
An under-voltage protection circuit will shut down all outputs if +5V output
is below the under-voltage threshold.
There is a 1.0 minute recovery delay from an under-voltage condition.
January 2002