Power requirements
Table 115
Power requirements
Voltage
± 15.0 V DC
+ 8.5 V DC
- 48.0 V DC
+ 5.0 V DC
553-3011-100
Standard 14.00
NT8D14 Universal Trunk Card
When the card is installed, the red Light Emitting Diode (LED) on the
faceplate flashes as the self-test runs. If the self-test completes successfully,
the card is automatically enabled (if it is configured in software) and the LED
goes out. If the self-test fails, the LED lights steadily and remains lit. The
LED will also light and remain lit if one or more units on the card becomes
disabled after the card is operating.
Each unit on the card connects to the backplane through an 80-pin connector,
the backplane is cabled to the Input/Output (I/O) panel, and the I/O panel is
cabled to the cross-connect terminal.
At the cross-connect terminal, each unit connects to external apparatus, such
as Central Office facilities or recorded announcement equipment. Each unit
connects to external apparatus by tip and ring leads which carry voice,
ringing, tone signaling, and battery.
Power requirements for the Universal Trunk Card are specified in Table 115.
Tolerance
± 5%
± 2%
± 5%
± 10%
January 2002
Idle current
306 ma
120 ma
346 ma
350 ma
Active current
306 ma
120 ma
346 ma
350 ma