I
= average number of digits that must be inserted as part of digit
manipulation
LOC
FCAS
where:
N = number of defined FCAS tables
M = average number of NPA codes per table
P = average number of the first digits in NXX codes
SCC
= number of entries in the SCC table
SDRR
SDE
= average number of SDRR entries for each SDRR block
ITGE
= 9 x ITEI, where ITEI is the number of Incoming Trunk Group
MDID
ranges regardless of which office codes they belong to). A maximum
of 20 ranges of office codes can be defined per locations code. (That
is, one office code and 20 ranges, or 20 office codes and one range
for each office code.)
Note 8
The protected data store requirements for CDP (on a per customer basis) are:
BASIC_ESN + SC x 3 + RL x (8 + 3 x RLE) + DME x (3 + I/4)
where:
BASIC_ESN = Size(ESN_DATA_BLOCK)
+ Size(NCTL_DATA_BLOCK)
Size(NCTL_DATA_BLOCK) = 306
SC
RL
Memory, Storage and CPU capacity
= number of on-net or virtual locations
= (N + 1) + N(M + 1) + MN[4 + (100P + 15)/16]
= number of supplemental digit restricted/recognized blocks
defined for npa, nxx, loc, spn
Exclusion Index
= (2 x number of total office codes) + (2 x number of total DID
= number of steering codes
= average number of route lists
Option 11C and 11C Mini
Page 61 of 544