Note 2
The size of a TTY block (in words) is calculated from:
Input Buff Data
CDR Link
HS Link
APL Link
PMS Link
Other
Note 3
For ACD features, the following additional storage per system is required:
K0 x [(K1 x CROUT) + (K2 x CPID) + (K3 x CDN) + CTM + (K4 + CRT)
+ (K5 x CCUST)] + (K6 x DN) + (K7 x PID) + (K8 x DN)
Where the multiplication constants (Ki) are:
Memory, Storage and CPU capacity
t + x,
where t = 2075 and
x is defined in the following table:
K0 = 0
if ACD-C package is not equipped
K0 = 1
If ACD-C package is equipped
K1 = 46
K2 = 14
If long report is selected
K2 = 42
If short report is selected
K3 = 80
K4 = 30
K5 = 240
K6 = 149
Option 11C and 11C Mini
Output Q
128
128 + 15
128 + 179 + 4
128 + 2
128