Meridian Modular Telephones
Local plug-in transformer
A single winding transformer equipped with a 10 ft. (3 m) cord of 22 AWG
two-conductor stranded and twisted wire with a modular RJ-11 duplex
adapter (refer to Figure 38) can provide the additional power needed to
operate the telephone and its options.
Do not plug any equipment (computer, modem, LAN card) other than
the Meridian Modular Telephone into the RJ-11 transformer adapter,
as damage to equipment may result.
120 V transformer (AO367335 or equivalent). The following minimum
specifications must be met by this transformer:
Input voltage: 120 V AC / 60 Hz
No load output voltage: 29 V AC maximum
Voltage at rated current: 26.7 V AC minimum
Rated load current: 700 mA
240 V transformer (AO367914 or equivalent). The following minimum
specifications have to be met by this transformer:
Input voltage: 240 V AC / 50 Hz
No load output voltage: 29 V AC maximum
Voltage at rated current: 26.7 V AC minimum
Rated load current: 700 mA
Note: You cannot wall mount the telephone over the wall jack when
using a transformer, due to the size of the RJ-11 adapter. Hang it above
or to the side of the jack and run the line and power cords to it.